VoiceAlert
2
User Manual
Extremely Important:
You must test reception of RF signal from each sensor and ensure that the
final required location of sensor is not too far from the final location of VA
2
, such that the RF signal fails to
reach (insufficient strength at far range). Use an assistant, to do range tests for all installed wireless sensors
and adjust the position of sensors in event of RF signal range issues. You can also make use of RF repeater
if repositioning the sensor is not possible.
Please make sure you are completely familiar with procedures for set up and installation of the various types
of WirelessAlert wireless sensors before attempting to code and install sensors for use with VA
2
.
Arming and Disarming of VA
2
and Activating Panic ….
Method 1:
Use the remote control to arm and disarm and activate panic.
Method 2:
Use the PSW key and enter the password on the VA
2
panel keypad to arm and disarm.
Method 3:
Use the instant arm and part arm keys on the panel main frame. You must allocate which zones
are part arm zones (indoor) and which zones are full arm (outdoor) by setting code 15.
Method 4:
Use codes 13 and 14 to set auto-arming and auto-disarming times for the two groups.
Method 5:
Use a landline telephone and or cell phone to arm (only works if
VA
2
has been connected to
landline and or GSM Dialler).
First Set code 07 -
To set the number of times the phone call will ring before the VA
2
answers the incoming
call.
Procedure for arming with phone is as follows:
•
Dial the telephone connected to VA
2
.
•
VA
2
will automatically answer the call.
•
Enter 9#1234
•
VA
2
will compare
entered password and if it matches stored password then arming will take place.
Procedure for disarming with phone is as follows:
•
Dial the telephone connected to VA
2
.
•
VA
2
will automatically answer the call.
•
Enter 0#1234
•
VA
2
will compare
entered password and if it matches stored password then disarming will take
place.
Voice Call Notification via Landline Connection….
Voice call notification makes use of existing landline and or connected GSM dialler (sold separately) to relay
zone trigger events as specific voice messages (Contact your WirelessAlert Agent for further information on
GSM Dialler).
Background info:
VA
2
will operate quite happily without being connected to landline or GSM dialler. Only if
you require voice calls notification, should you connect VA
2
to an existing landline or GSM dialler and
configure for dialling out in response to zone trigger.
Copyright InFocus Trading 111 cc, 2009
45
Disarm
Arm
Panic
No Function