VoiceAlert
2
User Manual
1. Set time for alarm clock buzzer to sound
Procedure:
•
Press
Return
(Inverted Arrow)
•
Press
PRG
•
Enter
12
•
Press
OK
•
Enter 1030 (alarm to sound at 10:30am daily.
•
Press
OK
•
LCD will Display as above
•
Press
Return
to exit
Related configuration codes
(You may need to set the following related configurations):
•
13
•
14
•
15
•
18
Code 13 – Set Grouped Zone Arming / Disarming: Automatic
(timed) Group 1
Prerequisite for basic VA
2
operation:
NO
Reason for Configuration:
Allows for specific zones to be armed / disarmed at unique times based on
specific security functions and different property environment requirements (e.g. A factory may require
specific zones to be armed at closing time (18:00) to monitor illegal entry of stock rooms or computer server
rooms….Zones could then be disarmed when factory opens (08:00) the following morning.)
Background info:
VA
2
has a two, automatic (timed) arming and disarming group functions. Up to eight
different zones can be allocated to a group. The arm and disarm times and the zones for the group need to
entered after the configuration code [13] for group 1.
Function Options:
1. Set time for automatic arm and disarm of Group1 zones.
Procedure
(e.g. set automatic arm (18:30) and disarm (06:30) times for zones 1, 2 and 3)
:
•
Press
Return
(Inverted Arrow)
•
Press
PRG
•
Enter
13
•
Press
OK
•
Enter 18300630123 (arm 18:30 daily, disarm at 06:30 daily, for zones 1, 2 and 3).
•
Press
OK
•
LCD will Display as above
•
Press
Return
to exit
Related configuration codes
(You may need to set the following related configurations):
Copyright InFocus Trading 111 cc, 2009
23