VoiceAlert
2
User Manual
Procedure:
•
Press
Return
(Inverted Arrow)
•
Press
PRG
•
Enter
50
•
Press
OK
•
Enter
01
•
Press
OK
•
Press the disarm button on the remote you wish to code.
•
You will hear a beep and the remote’s unique, 8 bit, RF code will then appear in the LCD screen. It
is recommended you record this remote RF code in a safe place for future reference. Do the same for all
additional coded remotes. (Please record all remote RF codes and their corresponding zone key numbers
in SID document: See Appendix 4).
•
Press
OK
•
Note the key has rolled over to the next number (02), for coding of the next remote.
•
Press the arm button on second remote you wish to code.
•
Press
OK
•
Proceed as above or press
Return
to exit
Related configuration codes
(You may need to set the following related configurations):
•
29
•
40
•
41
•
51
Code 51 – Coding of Wireless Sensors onto VA
2
’s Wireless
Zones
Prerequisite for basic VA
2
operation:
YES.
Reason for Configuration:
Use code 50 for coding wireless sensors onto VA
2
.
Background info:
Wireless sensors can be coded onto VA
2
’s wireless zones (1-8). The code key format
used for the wireless zones is (01-08).
The coding process links a wireless sensor’s 8 bit code with one of the zone keys (01-08). The sensor’s 8 bit
code will appear in the LCD screen when coding takes place. If you are using sensors with
DIP switch
for
manual setting of the 8bit code, then you can match the code across multiple sensors, allowing for more than
one sensor to trigger the same zone. This is very useful if you have a large property and need to have more
than one sensor monitoring a particular zoned area on the property.
Note:
The wireless RF signals from the sensors code onto the wireless zones sequentially, starting at key 01
and ending at code 08, so it is a good idea to record all sensor / zone information and keep this info stored in
a safe place for future reference (Please make use of WirelessAlert SID document for this purpose).
Note:
If a sensor has already been coded onto a particular zone, if you try to code it onto a second zone, the
VA
2
will beep a warning note to indicate sensor has already been coded.
Copyright InFocus Trading 111 cc, 2009
38