Using the SFI Menus
ProCam 1500 SFI Manual
20
Ch 3
1095900
TOOL NUMBER 1
COUNTERS
ADJUST CAMS
ADJUST FEED
STOP TIME
SHOW TIMING
LOAD TOOL #
USE CURSOR KEYS TO
MAKE SELECTIONS.
PRESS ENTER TO ACCESS
SELECTION.
Figure 3-16. Run menu
To adjust feed settings, select "Adjust feed". As the display indicates, you can adjust
"Feed length" (Figure 3-17).
USE THE UP AND DOWN CURSOR KEYS TO
INCREMENT OR DECREMENT THE FEED LENGTH
PRESS RESET WHEN DONE.
9.250 INCHES
FEED LENGTH
Figure 3-17. Adjusting feed length
Using the up and down CURSOR keys, you can make minor adjustments (if available).
Notice as you press either key, the value changes by .001 inch (1/1000) or less. This
information is directly sent to the servo feed and is immediately saved to the currently
loaded tool. Be sure to make a note of this change to your feed setup sheet for future
reference. Press the RESET key to exit from this display.
Troubleshooting
Whenever ProCam 1500 and the feed control unit are not successfully communicating,
the following message will appear on the LCD display. Check that all connections are
intact. Once communications is restored, you will no longer see this fault message.
THE PROCAM 1500 AND SERVO FEED CONTROL
ARE NOT COMMUNICATING. CHECK
THE CONNECTIONS AND BAUD RATES.
COMMUNICATIONS LOST WITH FEEDER
Figure 3-19. Communications fault message