Final checkout
If you have completed all procedures in this chapter, DiPro is almost ready for use. All
you need to do now is make a few test press runs to ensure that DiPro is working
properly. You will have to make some settings for a tool and load the tool number to run
the press. If you are not familiar with how to use the DiPro keyboard and displays to
create and load settings for a tool, begin to learn how to make settings now. Then
complete the steps below.
Follow these steps for final checkout:
1. Create a tool number and make settings for only one sensor. Set all other sensors
to NOT USED. Make the one used sensor a yellow sensor. Do not use a green
setting with a ready signal. Since this is a test, choose any name you want for the
sensor. Set stop type to top stop.
2. Load the tool number and go into Run mode.
3. Connect a yellow sensor to DiPro. For this test, use a simple sensor such as a
buckling sensor you can activate by hand.
Check and set direction of rotation of resolver
4. If you installed the position sensor, go to Step 5 (resolver rotation has already been
checked). If not, disable sensors using the display so DiPro does not stop the press
due to a sensor fault. Inch the press. Watch the angle/spm readout. If the angle of
the crankshaft decreases (goes from 359° towards 0°) instead of increasing, you
have to switch two wires on resolver connector TB105. Switch the wires in termi-
nals 2 and 5 (black and yellow). The angle will now increase as the ram moves.
Check for error messages when the press is run
5. Single stroke the press for a few strokes. See if the press stops automatically and
you get an error message on your screen. If no error message appears, go to Step 6.
If you installed a position sensor and a position sensor fault occurs, see Step 11
of the position sensor installation procedure. For other error messages, go to
Chapter 7 for a description of the error message. Follow the instructions under the
error message for solving the problem. Once you correct the problem, press
RESET and run the press again for a few strokes, checking for error messages. If
none occur, go to Step 6. If you cannot solve the problem, call Data Instruments'
technical advisors for help.
Check top stop circuit
6. Enable sensors using the keyboard and display. Run the press in continuous mode
and trip the sensor by hand to simulate a fault. Check that the press top stops and
that an error message is displayed on the screen. If so, go to Step 7.
If the press did not top stop and DiPro displayed an error message, there is a
problem in your top stop circuit. Recheck all wiring and trace the cause of the
problem. Do not continue with this procedure until the press top stops when you
trip the sensor.
Содержание dipro 1500
Страница 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Страница 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Страница 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Страница 119: ...DiPro 1500 Fault messages DiPro 1500 User Manual 110 Ch 7 1092000 This page intentionally left blank ...
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......