Using DiPro 1500 in Run mode
DiPro 1500 User Manual
95
Ch 6
1092000
Examples of a display for a green constant sensor
Here is an example of a display for a sensor set to green constant:
ON
OFF 70
SENSOR 3 SHORT FEED GREEN CONS
USE ANGLE KEYS
TO SET THE READY
SIGNAL. PRESS
RESET WHEN
DONE
0
90
180
270
360
45
270
ON
OFF
READY
260
SENSOR
marker wraps
around just like
ready signal bar
This is a short feed sensor set to green constant. Notice how the ready signal is set
so the sensor is on for the whole ready signal. This is a requirement for green
constant sensors.
The actuation marker shows that the sensor turns on and turns off outside the ready
signal, as required for a sensor set to green constant. Also notice how the sensor
actuation marker wraps around with the ready signal bar. "Sensor on" time is from
the triangle at 260 to the triangle at 70.
How DiPro displays sensor actuation times
DiPro does not show every stroke-to-stroke change when displaying sensor
actuation time. For sensors set to green and green quick check, it shows the earliest
on angle for the sensor and the latest off angle (that is, shows an increase in the
actuation angle). For sensors set to green constant, it shows the latest on angle and
earliest off angle (shows a decrease in the actuation angle).
For instance, if a green quick check sensor's on angle fluctuates between 190° and
195° from stroke to stroke, DiPro would show 190°. However, if the on angle
changed to 189° or lower, DiPro would immediately display the earlier on angle.
A green quick check sensor's off angle is recorded the same way. Only with the off
angle, DiPro displays the
latest
off angle.
For green constant sensors, DiPro would only show a change when the actuation
angle decreased, not increased. That is, it shows the latest on and earliest off. DiPro
displays actuation angles this way so you can set the ready signal using the worst
case actuation angles for the sensor. Another reason is because if DiPro showed
every change on the display, it might change so rapidly that you could not read it
from stroke to stroke.
To clear the displayed on and off angles for a sensor:
• Press the UP cursor key. This clears the actuation angles displayed for any
sensor. Zeros will be displayed. DiPro will display the actuation angles for
the very next stroke. You can press the key while the press is running or
stopped.
Содержание dipro 1500
Страница 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Страница 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Страница 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Страница 119: ...DiPro 1500 Fault messages DiPro 1500 User Manual 110 Ch 7 1092000 This page intentionally left blank ...
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......