12
6
Adjusting the total hardness
IMPORTANT
Before adjusting the total hardness, the manually
triggered venting must have been carried out
(
During the setting the device must not be in regen-
eration mode.
Determine the total hardness of the raw water.
See the table for the relevant setting value.
Up to serial no. 102846
Total hardness
in °dH
6
7
8
9
11
13
14
Setting value
100
125
150
160
200
230
250
Softened water
between
2 regenerations in
litres
1358 1083 905
820
689
575
531
Total hardness
in °dH
15
17
19
20
21
25
29
Setting value
270
300
340
350
375
450
525
Softened water
between
2 regenerations in
litres
500
453
413
394
379
317
254
From serial no. 102847
Total hardness
in °dH
6
7
8
9
11
13
14
Setting value
100
125
150
170
200
240
250
Softened water
between
2 regenerations in
litres
1083
866
728
650
531
453
433
Total hardness
in °dH
15
17
19
20
21
25
29
Setting value
280
300
330
350
395
485
525
Softened water
between
2 regenerations in
litres
394
354
315
295
276
236
197
INFO
The setpoints in the dark colored columns are directly
affixed to the setting disk (3). The other values are approx-
imate values.
Press down the setting button (1).
Turn the setting button (1) until the arrow is exactly opposite the
arrow on the setting disc in the viewing window (2).
INFO
Each tooth deviation relates to approx. 20 litres of soft
water more or less up until the next regeneration.
Start up the warewasher connected to the MonoMatik 3.
Fill up the warewasher.
Check that the hose connections do not leak.
7
Check setting
Flush out 10 litres.
Measure the total hardness.
If necessary vent again (
chapter 5) and adjust the total hard-
ness (
chapter 6).
8
Instructing personnel
Instruct personnel in the following points:
Salt refilling
Maintenance and care