11
Commissioning Instructions
for the Winterhalter MonoMatik 3 Softener
These instructions are intended for correct commissioning of the
MonoMatik 3 softener by an authorised Winterhalter service techni-
cian.
1 Testing installation
Test the following points:
Is it installed according to the operating instructions and the
connection diagram?
Is the water inlet temperature in accordance with the connec-
tion diagram?
Are the water pressures in accordance with the connection
diagram?
2
Converting total hardness
Water hardness is specified in the German degree of hardness (°dH)
in these instructions. Other units of measurement are used in other
countries.
Measure the total hardness and convert into the German degree
of hardness (°dH) using the following table:
°dH
°e
°TH
mmol/l
German hardness
1°dH=
1.253
1.78
0.179
English hardness
1°e=
0.798
1.43
0.142
French hardness
1°TH=
0.560
0.702
0.1
mmol/l
1mmol/l= 5.6
7.02
10.00
3
Adjusting and installing the brine valve
Remove the brine valve.
Check whether the distance (a) is
17 mm. Adjust as necessary.
Install the brine valve.
Ensure that the valve base (1) is
sitting in the recess of the container
base and that it is possible to move
the float cup vertically approx. 6 mm.
Insert the connector (2) into the control head.
4
Adding regeneration salt
Caution
Possibility of damage due to incorrect salt.
Only use high-purity evaporated salt (approx. 15 mm
granularity or in tablet form) marked as regeneration salt
for softeners. Do not use any other types of salt e.g.
table salt, rock salt or de-icing salt. These may contain
components that are not soluble in water.
Fill 5 litres of water into the container.
Pour approx. 10 kg of regeneration salt into the container.
5
Venting / manually triggering regeneration
Switch off the warewasher connected to the MonoMatik 3.
Open the water supply to the MonoMatik 3 slowly.
Remove the sticker on the screw (1).
Using a Phillips screwdriver, push the screw (1) down so that
the control disc rotates.
Turn the screw (1) slowly in a clockwise direction until the
regeneration begins (approx. 1 o'clock position).
Air and water must be emitted from the hose with regenera-
tion waste water.
After approx. 10 minutes no more water may be emitted
from the hose.
Do not force the regeneration manually. The unit must run the
regeneration to the finish by itself.