background image

Winterhalter Gastronom GmbH

Pf. 1152   D-88070 Meckenbeuren

OI   GSR36/GSR36E   89003475   09/00 sch   P.8

11. Special Equipments

11.1 Execution with reversible rinse temperature

This machine is employed when a change-over between two rinse temperatures is required. The machine may
only be operated according to the describrd operating instructions.
water.

A) Operating controls

1

Selector button rinse temperature

By pressing this button the required rinse temperature is selected. When
switched on, the pilot light is lit, the high temperature is selected for
rinsing. When the button is switched off, the low rinse temperature is
selected.

B) Function of the reversible rinse temperature

With the the selector button „rinse temperature“ may be changed over between the high and the low rinse tem-
perature.

Important:

The factory adjustment of the high temperature is 85°C and the low temperature is 65°C.

- At first press the button to switch to the high rinse temperature - the pilot light in the button is lit.

With the high rinse temperature and the recommended rinse aid, an optimum drying result is guaranteed. We
recommended the high rinse temperature for washing dishes.

- When pressing the button again, you switch to the lower rinse temperature. The pilot light in the button extin-

guishes.

When washing glasses, the low rinse temperature has to be selected. The high rinse temperature may cause
corrosion at the glasses and may lead to dull glasses.

The adjustment of the rinse temperatures to the required values is exclusively done by the Winterhalter after-
sales-service. This is done during the first commissioning or during installation works for the reversible rinsing.

1

Содержание GSR 36

Страница 1: ...perator You can operate this machine without danger if you observe the following indications Only work with this machine if you have been instructed on the handling and the operati on Operate the mach...

Страница 2: ...ly after finishing all connection works your dishwasher is ready for commissioning 4 Operating and control instruments 1 Mains switch By pressing the machine is switched on lights up when switched on...

Страница 3: ...f appr 85 C and afterwards the tank hea ting starts to heat up the tank water to the operating temperature of appr 58 C During heating up the white pilot light ready for operation 2 is lit The heating...

Страница 4: ...rectly into the respective rack Insert the rack into the machine Close the door If necessary use the manual cold prerinsing 5 Option Engage the programme by pressing one of the buttons which is adequa...

Страница 5: ...e lid for the float switch This corresponds to two bags of Winterhalter SoftMatik regenerating salt 1000g It is easier to fill in the salt when using the enclosed funnel Remove the remaining salt from...

Страница 6: ...ace strainers again into the machine Close isolation valve on site Switch off main switch on site Clean the machine outside with a soft cloth amd appropriate cleaning agents It is recommended that Win...

Страница 7: ...oducts which have been developed by us and are suitable for our machines All indications about quantity and weight of detergent and rinse aid refer to Winterhalter pro ducts Besides the daily cleaning...

Страница 8: ...changed over between the high and the low rinse tem perature Important The factory adjustment of the high temperature is 85 C and the low temperature is 65 C At first press the button to switch to the...

Отзывы: