140721
PRODUCT
MANUAL
PCM-MIO-G-1 21
Address Codes
Span Codes
The span for each channel is set by loading the desired value into the data registers, then issuing one of the span
commands. The last 4 bits set the span as shown below. The rest of the data should be set to
0
.
Readback Enable
Each time a command is issued to one of Linear Tech LTC-2704 devices, the value of one of the buffers is simultaneously
shifted out of the device. Except when issuing one of the specific readback commands (Ax, Bx, Cx, Dx), the data
returned corresponds to the Readback Pointer from the previous command as shown in the
Command Codes
Table
. The
Readback Enable bit must be set to
1
to read this data.
Note:
If the Readback Enable bit is set to
0
, a read of the DAC data registers will return the last value written to that
register not the Readback value of the actual buffers.
A3
A2
A1
A0
n
Readback
Pointer n
0
0
0
0
DAC A
DAC A
0
0
1
0
DAC B
DAC B
0
1
0
0
DAC C
DAC C
0
1
1
0
DAC D
DAC D
1
1
1
1
All DACs
DAC A
Codes not shown are reserved and should not be used
S3
S2
S1
S0
Span
0
0
0
0
Unipolar 0V to 5V
0
0
0
1
Unipolar 0V to 10V
0
0
1
0
Bipolar -5V to 5V
0
0
1
1
Bipolar -10V to 10V
0
1
0
0
Bipolar -2.5V to 2.5V
0
1
0
1
Bipolar -2.5V to 7.5V
Codes not shown are reserved and should not be used