5044744
62
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMatic EAV
Installation, Operating and
Maintenance Instructions
Figure 3.6.2-9: Installation blueMatic EAV with
Fingerprint SOMMER
E FD
(sash side)
green / yellow
= input for external
potential-free contact
(e.g. unlocking via
intercom / open button)
Notice!
max. 40 m extendable
(min. 0,8 mm2)
Connection from sash
part cable transition
to the radio receiver
E RX
(plug-in)
Connection from radio
receiver E
RX to the motor
housing EAV (plug-in)
Connection from radio
receiver E
RX to the fingerprint
E FD
(plug-in)
Caution!
Change jumpers from:
Factory setting
= down on new
setting, for blueMatic
EAV = top
}
free
white + 12 V DC
brown 0 V
green
yellow
grey
pink
}
external opening
signal
Notice:
In the combination of the
SOMMER E FD
fingerprint with Winkhaus
blueMatic EAV MANDATORY: do
not change the specified
assignment of the Winkhaus screw
terminal (white = + 12 V, brown =
0 V) / mount the Winkhaus screw
terminal as shown in the
illustration.
Содержание blueMatic EAV