3.4. Access control system, transponder set
Prerequisites for installation:
• The transponder signal is processed in the reader/control unit.
• This unit has to be installed in a standard flush-type box inside the building (close to
the door).
NOTICE!
Should you want to accommodate the control unit and button in the same
flush-type box, this one must have a depth of 65 mm [2.559“].
• Unless you use a button beside the door, you will have to install a flush-type box
with a filler panel for the reader unit.
DANGER!
For safety reasons, you are not permitted to install it in a
flush-type box with a 230 V switch or socket outlet!
• The transponder antenna is located in a housing in exposed installation and is to be
installed in a weatherproof zone outside the entry door.
• Do not mount the antenna directly on metal as its range could be decreased drasti-
cally.
• Do not mount any other antenna within a radius of 1 m [1.094 yd]!
NOTICE:
If you plan installations on a metal substructure, you will have to use a
wooden board and spacer bolts, if applicable, or large bore holes to ensure
the proper function of the antenna! To test the scanning performance, you
may have to tentatively install it on site, if applicable!
• Connect the cable of the antenna to the reader/control unit.
• We recommend: Lay a reserve pipe from the antenna to the reader unit.
3. Installation