51
Troubleshooting
WARNING
BEFORE PROCEEDING, READ AND UNDERSTAND THE SAFETY INFORMATION CONTAINED IN
THE SAFETY SECTION OF THE WINE GUARDIAN MANUAL.
Typical Start-up Problems
Possible Cause
Loose, improper or defective
thermostat or humidistat cable
Solution
Check power, and thermostat
or humidistat cable
Incorrect thermostat or
humidistat (optional) settings
Check the thermostat and optional
humidistat set up for the application
Changed settings on the thermostat
A common problem is not waiting long
enough for the internal timers to complete
their timed delay
Unit Does Not Start-up
Power Switch Light is Off
Possible Cause Solution
Switch not on Turn on switch
No power to outlet Check circuit breaker and wiring
Unit not plugged in Plug in the unit
Power switch light is on and the thermostat light is off
Possible Cause Solution
No power to thermostat Check main control board for L.E.D.
indication
Check wiring for loose, broken or frayed
connections
Check wiring for proper splicing
Remote interface controller may be faulty
Power switch light is on and the thermostat light is on
Possible Cause Solution
Thermostat is not set up properly Check thermostat set up in the guide.
Press fan ON switch to check evaporator
fan only
IMPORTANT
This section is intended as a diagnostic aid only. For detailed repair or parts replacement
procedures, contact a qualified service company. Check the following table for some
solutions before calling a service technician.
Содержание D0200
Страница 12: ...12 Overview Illustration of the Wine Guardian Unit Fig 1 Fig 2...
Страница 13: ...13 Overview Illustration of water cooled system Fig 3 Fig 4...
Страница 14: ...14 Wiring diagrams D025 and D050 Fig 5...
Страница 15: ...15 Wiring diagram D088 and D200 Fig 6...
Страница 16: ...16 Wiring diagram water cooled D025 and D050 Fig 7...
Страница 17: ...17 Wiring diagram water cooled D088 and D200 Fig 8...