Model Number
D025
D050
D088
D200
Performance
Nominal Compressor
HP
.33
.50
1
2.5
Net Cooling Capacity*
@ 70 Deg F Ambient
BTUH
3300 / 3650
5600 / 6050
8400 / 9100
16200 / 17750
@ 80 De
g F Ambient
BTUH
3000 / 3300
5300 / 5700
7800 / 8450
15200 / 16550
@ 90 Deg F Ambient
BTUH
2800 / 3050
4850 / 5275
7300 / 7900
14100 / 15350
Controls
Type
Room mounted non
-
programmable thermostat
Accuracy
± 2°F
Evaporator Section
Fan
Motor Size
Watts
75
100
195
240
Rated Air Flow
CFM
235
430
510
870
Air Flow with 25' flex duct
CFM
207
400
485
(*4.*) 740
Air
-
cooled Condenser Section
Fan Size
Watts
75
100
195
240
Rated Air Flow
CFM
253
400
500
870
Air Flow with 25' flex duct
CFM
220
365
475
(*4*) 740
Water
-
cooled condenser Section (option)
Water usage at 40 Deg F rise
GPM
0.30
0.60
1.20
2.50
Pressure drop
PSI
0.40
0.40
0.85
1.20
Pipe connection size (in/out) O.D.
Inches
0.63
0.63
0.63
0.63
Heat
Type
Integral electric heater coil
Capacity
Watt/btuh
1000/3413
1000/3413
2000/6826
2000/6826
Temperature rise
-
including fan
Deg F
13.5
8.6
12.0
8.1
Humidifier
Type
Removable Drip pad with integral fan
Supply water temp of 60 Deg F
gal./day
1.6
Supply water temp of 90 Deg F
gal./day
3.5
Supply water temp of 120 Deg F
gal./day
5.1
Control
Cellar mounted digital humidistat
Electrical Requirements
Power Requirements
V/P/H
115/1/60
115/1/60
230/1/60
230/1/60
Current Draw
-
Cooling mode
Amps
8.6
11.9
9.0
16
Current D
raw
-
Heating mode
Amps
9.4
9.6
9.6
10
Minimum Circuit Size
Amps
15
15
15
20
Optional Low Ambient
Amps
0.4
0.4
0.2
0.2
Optional Humidifier
Amps
0.3
0.3
0.2
0.2
7000 Performance Drive | North Syracuse, New York 13212 USA
800-825-3268 | 315-452-7400 | Fax 315-452-7420 | www.wineguardian.com |
1.
Net cooling capacity at entering temperature and humidity conditions of 55 Deg F and 60% RH / 60 Deg F and
60% RH and at rated airflow. Reduce capacity by 3%for each 10% reduction in either condenser or evaporator
airflow, 5% for both.
2.
Wine Guardian reserves the right to make changes to this document without prior notice at its sole discretion.
3.
All ratings at sea level.
4.
D200 air flow based on 0.35 inches Wine Guardian external static pressure using 50’ of flexible ductwork, grilles
and collars . Rev. 3/2012
Содержание D0200
Страница 12: ...12 Overview Illustration of the Wine Guardian Unit Fig 1 Fig 2...
Страница 13: ...13 Overview Illustration of water cooled system Fig 3 Fig 4...
Страница 14: ...14 Wiring diagrams D025 and D050 Fig 5...
Страница 15: ...15 Wiring diagram D088 and D200 Fig 6...
Страница 16: ...16 Wiring diagram water cooled D025 and D050 Fig 7...
Страница 17: ...17 Wiring diagram water cooled D088 and D200 Fig 8...