background image

11 

 

Wiring Diagram 

– Freestanding Humidifier (50Hz) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 99H0173-20

Страница 1: ...m airinnovations com Wine Guardian reserves the right without notice to make changes to this document at its sole discretion Please visit our web site for the most current version of the Wine Guardian...

Страница 2: ...ram Freestanding Humidifier 50Hz 11 Humidifier Dimensions Freestanding 12 Humidifier Dimensions Integrated 13 Installation 14 Pre Installation 14 Freestanding Installation 15 Integrated Installation S...

Страница 3: ...ion between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician...

Страница 4: ...Installation and maintenance of this equipment is to be performed only by qualified personnel who are familiar with local codes and regulations and are experienced with this type of equipment Exposur...

Страница 5: ...ving Inspecting and Unpacking When receiving the unit ensure the unit is undamaged and includes all ordered accessories Note Wine Guardian units are factory assembled and tested prior to shipment Wine...

Страница 6: ...ine Guardian system Integrated humidifier that mounts directly to the side of any ducted or split Wine Guardian system Humidifier is controlled by the Remote Interface Controller via communication cab...

Страница 7: ...ir in the air at a given air condition Moisture water that has been evaporated into the air NEC National Electrical Code Set point the desired temperature or humidity that is set on the Thermostat or...

Страница 8: ...er does it contribute to more humidification The drain volume is too much for just a bucket A gravity drain line should be piped to an open floor or sink drain or a condensate pump may be used where a...

Страница 9: ...9 Wiring Diagram Integrated Humidifier 60Hz 50Hz...

Страница 10: ...10 Wiring Diagram Freestanding Humidifier 60Hz...

Страница 11: ...11 Wiring Diagram Freestanding Humidifier 50Hz...

Страница 12: ...12 Humidifier Dimensions Freestanding...

Страница 13: ...13 Humidifier Dimensions Integrated...

Страница 14: ...ing unit plug in the unit If the unit is to be connected to a cooling unit you need to wire the humidifier to the cooling unit and the cooling unit must be turned on Refer to page 14 Set the humidista...

Страница 15: ...onnection at the top of the humidifier see Fig 7 on page 14 A shut off valve not provided is recommended to isolate the humidifier from the water system when needed 5 Install a 1 2cm flexible drain li...

Страница 16: ...16 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8...

Страница 17: ...captive latches to secure the access panel to the humidifier housing See Fig 9 on this page 3 Remove side access panel on the side of the cooling unit where you wish to mount the humidifier 4 Install...

Страница 18: ...seen on the next page to the Wine Guardian unit with the 4 8 32x1 25 screws provided 4 Hook the cleat at bottom of the humidifier over the bottom edge of the opening on the adaptor plate 5 Rotate the...

Страница 19: ...19 Fig 11...

Страница 20: ...en on the next page to the Wine Guardian unit with the screws that were removed from the door 4 Hook the cleat at bottom of the humidifier over the bottom edge of the opening on the adaptor plate 5 Ro...

Страница 21: ...21 Fig 12 Fig 13...

Страница 22: ...22 Fig 14 Fig 15...

Страница 23: ...button and hold it down for five 5 seconds The screen will advance to the set up menu and 1 F will appear on the screen see pictorial on page 23 For 50Hz models default will be 1 C 3 Continue to pres...

Страница 24: ...24...

Страница 25: ...CONTAINED IN THE BOX WITH THE HUMIDISTAT WE RECOMMEND YOU FOLLOW WINE GUARDIAN S HUMIDISTAT INSTRUCTIONS AND SIMPLY RETAIN THE HUMIDISTAT MANUFACTURER S INSTRUCTIONS IN A FOLDER ALONG WITH THE WINE G...

Страница 26: ...ir The drain system may also trap dust and dirt When water no longer stays on the pad or mineral build up has started to reduce airflow the pad needs to be replaced Suggested Maintenance Schedule Mont...

Страница 27: ...its are present install a new evaporative pad Replace the pad by lifting up on the spring loaded drip tray Note the pad must be installed in the correct position There is a black spot painted on one e...

Страница 28: ...tall the strainer in the valve inlet replace the tubing and tighten the compression nut Double wrench to prevent damage and leaks 7 Disconnect the water line on the outlet of the solenoid valve 8 Remo...

Страница 29: ...ANY INCIDENTAL OR CONSQUENTIAL DAMAGES Wine Guardian will not be responsible for any costs or liabilities whatsoever resulting from improper installation or service of its equipment In the event that...

Страница 30: ...by the Warranty occurs contact Wine Guardian for authorization to proceed with corrective action Do not return any parts or incur any charges for which you expect to be reimbursed under this Warranty...

Отзывы: