28
Water Line Maintenance
1.
Start by disconnecting the electrical power and shutting off the water supply.
2.
Remove front cover of humidifier or remove humidifier from ducted Wine
Guardian unit (depending on your set-up).
3.
Disconnect the water line at the inlet to the solenoid valve.
4.
Remove the in-line strainer from inside the inlet fitting using caution to avoid
penetrating the strainer and rendering it useless.
5.
Clean the strainer by flushing under hot water or immersing in a demineralizing
solution to break down the mineral deposits. Inspect and replace the strainer if it
cannot be cleaned or if the screen is damaged.
6.
Reinstall the strainer in the valve inlet, replace the tubing, and tighten the
compression nut. Double wrench to prevent damage and leaks.
7.
Disconnect the water line on the outlet of the solenoid valve.
8.
Remove the orifice from the copper tube and make sure this small opening is
unplugged.
9.
Replace the orifice and reconnect the outlet water line. Double wrench to prevent
leaking.
10.
Reinstall the in-line strainer and reconnect the inlet water line. Double wrench to
prevent leaking.
11.
Turn on water supply and reconnect electrical power to the humidifier.
12.
Check to be sure the water supply tube is aimed at the center of the distribution
tray between the two center holes. This will ensure even distribution off water
across the entire tray and equally into each of the six holes, thereby evenly
wetting the entire surface of the drip pad.
Содержание 99H0173-20
Страница 9: ...9 Wiring Diagram Integrated Humidifier 60Hz 50Hz...
Страница 10: ...10 Wiring Diagram Freestanding Humidifier 60Hz...
Страница 11: ...11 Wiring Diagram Freestanding Humidifier 50Hz...
Страница 12: ...12 Humidifier Dimensions Freestanding...
Страница 13: ...13 Humidifier Dimensions Integrated...
Страница 16: ...16 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8...
Страница 19: ...19 Fig 11...
Страница 21: ...21 Fig 12 Fig 13...
Страница 22: ...22 Fig 14 Fig 15...
Страница 24: ...24...