For the Service Technician
4.7 Service level
Values, restart temperature, burnout, language and actuator test can be displayed and modified on the Service
level.
Structure on the Service level:
Inf
ormation!
Only trained service personnel may perform system modifications on the Service level.
Actuator test
Menu
Temp. Boiler
Temp. chamb.
Fan-speed
Pos. Prim. airfl.
Pos. Sec. airfl.
O2 signal
O2 heat current
Temp. Exhaust
Values
Parameters
Automatic
ignition
Restart
temperature
Settings
Operator level
Settings in the operator level
see LogWIN
Operating Manual.
Service level
(Reserved for trained service
personnel only)
Information level
(see LogWIN
operating instructions)
MES Module
1
(see separate instructions for
InfoWINplus Master operation)
InfoWINplus basic
settings
(see section 4.8)
1 only displayed when an MESplus control is present and this has been adjusted by a trained service technician in the basic settings.
Burnout
Induced draught fan
Primary airflap
Secondary airflap
O2 heating
Automatic ignition
Install display module
Language selection
Temperature format
Time format
Date format
Weight
Automatic ignition
Yes
No
Burnout
automatic detection
normal
Ember quantity
Boiler temperature
for restart
65
°C
75 °C
Language
selection
Boiler
SMS
MB
ELG
Ethernet
Update Software
Update Firmware