31
3.
For the Electrician
– Make sure that the plugs for the door switch, flue gas sensor (accessories) and air control are correctly con-
nected in the control panel. Cables and plugs are inscribed – Fig. 63.
– The connections for the MESplus system control are on the terminal blocks (screwless spring-type terminals)
at the rear in the control panel and should be connected with fine-wire PVC sheathed cables – Fig. 63.
Information!
Be sure to note the separate wiring of the extra-low voltage line (0–12 VDC) and low-voltage line
(230 V AC)! Route cables in the cable ducts available – Fig. 63.
Information!
Electrical cables should be routed in the cable ducts intended for this purpose and are not allowed
to be routed over the cleaning cover. The space above the cover must be accessible for cleaning.
Connecting automatic ignition (accessory)
see separate assembly instructions provided.
Information!
After connecting the cables, remove any remaining assembly materials (e.g., wire cuttings) from the
control panel.
Fig. 63 Control panel open, connecting plugs – front view
Cable duct
Low-voltage
(230 V AC)
Réglettes de
bornes MESplus
Cable duct
Extra-low voltage
(0–12 VDC)
Air control
Plug X 14
Air control
plug X6/X7
Flue gas sensor
(accessories)
Plug X11
(ac
Door switch
plug X15