OPM-133/E

CONNECTING THE LOADS

The engine-generator covered in this manual was designed 
for portable use. Do NOT operate indoors. The unit should 
be stored in a warm, dry location. Move the unit outdoors 
to a flat, dry location for use.

WARNING: PERSONAL DANGER:

Operating any engine driven generator without 
proper air flow can result in personal injury or death. 
DO NOT operate this unit inside a home or garage, 
near vents or windows, or anywhere carbon monoxide 
gas could accumulate. 

APPLYING THE LOADS

Allow the engine to warm up for two or three minutes 
before applying any load. This will allow the engine to 
reach normal operating temperature and oil to circulate 
throughout the engine. A short warm-up time will permit 
the engine to work more efficiently when the load is 
applied and will reduce the wear in the engine, extending 
its life. Receptacles have been provided to allow loads to be 
connected to the generator. 

The loads should be added one at a time. If a large motor 
is being started: or multiple motors are being started, they 
should be started individually and the largest should be 
started first.

CAUTION: EQUIPMENT OVERLOAD

Keep the generator load within in the generator and 
receptacle nameplate rating. Overloading may cause 
damage to the generator and/or the loads.

Most electric tools and appliances will have the voltage and 
amperage requirements on their individual nameplates. 
When in doubt, consult the manufacturer or a local 
electrician. The nameplate amperage rating for electric 
motors can be misleading. See “Starting Electric Motors” in 
the Unit Capabilities. 

These engine-generator sets are inherently self regulating 
based on engine speed. The engine governor will 
automatically adjust itself to the load. No harm to the 
generator will result if it is operated with no load connected. 

CAUTION: EQUIPMENT DAMAGE

Diesel engines should never be run for an extended 
period of time with a very light load or no load on 
them, it may do permanent damage to the engine if 
run under these conditions.

Proper utilization of the receptacles located on the control 
panel is necessary to prevent damage to either the 
receptacles or the generator. The generator is a limited 
source of electrical power, therefore, pay special attention 
to the receptacle and generator ratings. The nameplate 
rating can be obtained through a single receptacle as long 
as the receptacles amperage rating is not exceeded.

GROUNDING

Proper grounding of your generator is application 
dependent. Carefully evaluate your planned use of your 
generator to understand which grounding you require. 
If you are not sure what to do, contact a competent 
professional to assist you. The NFPA 70 250:34-35 are good 
technical references.  

STANDARD PORTABLE GENERATOR

Your WINCO portable generator ships with a bonded 
neutral. You can safely use this generator without external 
grounding as long as all loads are powered through the 
receptacle panel. 

VEHICLE-MOUNTED GENERATOR

Your WINCO portable generator ships with a bonded 
neutral. When mounted to a vehicle to safely distribute 
power it is necessary that the generator frame is bonded 
to the vehicle frame. The generator should only supply 
equipment that is cord and plug connected through 
receptacles mounted on the generator or the vehicle. 

PERMANENTLY INSTALLED GENERATORS

This WINCO portable generator ships with a bonded 
neutral and overcurrent protection. NFPA 70 refers to this 
as a “separately derived system.” When connecting it to a 
building a transfer switch specifically designed for GFCI and 
bonded neutral generators is required. 

WIRING

Plug your tools such as drills, saws, blowers, sump pump, 
and other items to be powered directly into the generator 
receptacles. Before plugging in all the tools and cord 
sets, recheck the rating of the generator set. Be sure it 
can handle the intended load and is compatible with the 
voltage, phase, and current ratings. ‘Hard wiring’ this unit 
directly into a temporary construction site electrical system 
is NOT A SIMPLE DO-IT-YOURSELF JOB. For your safety, all 
wiring must be done by a qualified electrician and conform 
to the National Electric Code and comply with all state/local 
codes and regulations. Check with local authorities before 
proceeding.

WARNING: PERSONAL DANGER

A fully isolated, double pole double throw manual 
transfer switch must be installed any time a generator 
is being connected to an existing distribution system.

Содержание W6010DE/I

Страница 1: ...ver need to contact us concerning this unit it will help us to respond to your needs faster MODEL ________________________________________________ SERIAL NUMBER _______________________________________...

Страница 2: ...TROUBLESHOOTING 18 WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation an...

Страница 3: ...sent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator se...

Страница 4: ...0DE I J 43 21 5 W6010KE 03 A 40 20 GENERATOR Generator Manufacturer Mecc Alte Spa Generator Model Number S16W 130 A Part Number 16346 006 Rotor Resistance 3 95 Ohms Stator Resistance 0 360 Ohms Cap Wi...

Страница 5: ...ED USES DO NOT operate generator where it could get wet or have pooling water near it This generator is NOT weatherproof Failing to keep generator in a dry area may cause an electrical shock resulting...

Страница 6: ...esent the 120 volt output legs of this generator Up to 2 580 watts at 120 volts 43 Amps can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 2...

Страница 7: ...evel be sure you properly tighten the oil fill cap NOTE This engine generator must be on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping th...

Страница 8: ...ry presents a risk of electrical shock and high short circuit current The following precautions must be observed when working with batteries 1 Remove watches rings and other metal objects 2 Use tools...

Страница 9: ...as a battery charging circuit to recharge dead batteries LIFTING EYE INSTALLATION In the bag of parts for the lifting eye ensure all of the required materials are included 2 qty 5 16 18 x 2 25 button...

Страница 10: ...osition The lever is located under the key switch as pictured 3 Turn key to 1st position Ref A 4 Turn key to the 2nd position starting Ref B A B 5 Return key to 1st position when engine is running Ref...

Страница 11: ...revent damage to either the receptacles or the generator The generator is a limited source of electrical power therefore pay special attention to the receptacle and generator ratings The nameplate rat...

Страница 12: ...stored while the generator is connected This generator is GFCI protected so the transfer switch needs to be GFCI compatible If the transfer switch is not GFCI compatible the breaker on the generator w...

Страница 13: ...ual are approximately as follows under varying loads LOAD vs OUTPUT Generator Load Speed RPM Frequency Hz Voltage 120V Recpt 240V Recpt None 3690 61 5 125V 258V Half 3600 60 0 120V 240V Full 3510 58 5...

Страница 14: ...s generator is capable of producing 21 5 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatibility Remember that power taken from C reduc...

Страница 15: ...Check dry air cleaner Fuel tank cleaning Clean cooling fins Replace engine oil Replace oil filter Replace fuel filter Set and clean injectors Rocker arm adjustment Drain Bolt C Replace oil drain plug...

Страница 16: ...is excessively dirty replace with a new filter You can use pressurized air not to exceed 30 psi to clean the filter Always blow the compressed air from inside to the outside F Clean the dirt from the...

Страница 17: ...ubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the...

Страница 18: ...uit breaker trips Defective load Defective receptacle Excessive load GFCI type of load i e a building with bonded neutral Voltage too high Engine speed is too high Generator overheating Overloaded Ins...

Страница 19: ...19 OPM 133 E WIRING DIAGRAM...

Страница 20: ...nd Purchaser s sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use...

Отзывы: