IMPORTANT!

PLEASE READ THIS ENTIRE MANUAL BEFORE USING RECLINER.  DO NOT INSTALL, MAINTAIN OR OPERATE 
THIS EQUIPMENT WITHOUT READING AND FOLLOWING THIS MANUAL. OTHERWISE, SERIOUS INJURY AND/ 
OR DAMAGE TO PRODUCT MAY OCCUR.

THE INFORMATION CONTAINED IN THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. PHOTOS ARE 
REPRESENTATIVE OF THE PRODUCT AND MAY VARY SLIGHTLY FROM ACTUAL PRODUCTION MODELS. 

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE!

NO PART OF THIS MANUAL MAY BE DUPLICATED IN ANY FORM WITHOUT THE PRIOR WRITTEN CONSENT OF 
WINCO MFG, LLC.  UNAUTHORIZED DUPLICATION MAY RESULT IN CIVIL PROSECUTION TO THE MAXIMUM 
EXTENT ALLOWED BY LAW.

INTENDED USE STATEMENT

Intended Use:

 

Vero is a recliner for use in medical settings. It is designed to provide comfort for patients seated up 

to 8 hours at a time while receiving treatments such as Dialysis, Infusion or recovery from surgical procedures where 
positional adjustments are beneficial. The recliner is also suitable for general use in many medical settings such as, 
but not limited to hospital room chair, waiting room chair, convalescent home chair, etc.

Winco assumes no responsibility for damage or injury caused by the improper assembly, 

installation, use or maintenance of this product.

Products with the following markings are intended for commercial use only.

SYMBOLS

TYPE B APPLIED PART

FOLLOW INSTRUCTIONS

DC VOLTAGE

GENERAL WARNING SIGN

PINCH POINT 
WARNING SIGN

TRENDELENBURG

SYMBOL FOR MANUFACTURER

TRANSPORTATION, STORAGE, HANDLING AND DISPOSAL INSTRUCTIONS

The product should be 

transported

 in factory packaging, inside an appropriate medium for the destination, i.e., air/sea cargo con-

tainers. The product should be 

stored

 in an environment that will inhibit rust/mold formation.  Winco also recommends not leaving 

the product in the factory packing in excess of 3 months. The product should always be 

handled

 in a manner consistent with the 

user instructions, and in a manner to prevent contamination after each use.  The product has many recyclable components and to 
the extent practical, all effort should be used to recycle responsibly.  Otherwise the product components shall be 

disposed

 of in 

accordance with local statues.

Содержание vero

Страница 1: ...PLEASE DO NOT DISCARD THIS MANUAL KEEP FOR FUTURE REFERENCE AND TRAINING OWNER S OPERATING MAINTENANCE MANUAL Model 6Y48 39 00 00 00 D6 Shown...

Страница 2: ...ORTATION STORAGE HANDLING AND DISPOSAL INSTRUCTIONS 3 IMPORTANT SAFETY INFORMATION 3 6 ASSEMBLY INSTRUCTIONS 7 8 ATTENDANT OPERATING INSTRUCTIONS 9 14 OCCUPANT OPERATING INSTRUCTIONS 15 16 GENERAL MAI...

Страница 3: ...al use in many medical settings such as but not limited to hospital room chair waiting room chair convalescent home chair etc Winco assumes no responsibility for damage or injury caused by the imprope...

Страница 4: ...e plug from outlet Pull plug only to remove cord 10 Clean switch with a damp cloth only Warranty will be VOID if liquid is introduced into switch mechanism 11 Extension cords are not recommended 12 DO...

Страница 5: ...to satisfy customer expectations for typical equipment configuration Devices qualifying as double insulated require different testing examination procedures than Class I Grounded devices If your faci...

Страница 6: ...ended foot support or other similiar parts 7 DO NOT use the recliner if the Trendelenburg Damper Gas Spring is removed or damaged 8 DO NOT use recliner for transporting in or with ANY type of vehicle...

Страница 7: ...g brackets with the recline mechanism B WARNING Keep hands clear of connection points or injury may occur IMPORTANT Winco recommends two people be used for step 4 Be careful not to tear or puncture vi...

Страница 8: ...mechanism until the middle hole of the mounting bracket A is aligned with the middle hole of the recline mechanism B 6 Install knobs tethered to back and fully tighten to a secure fit IMPORTANT Test...

Страница 9: ...to position shown Total Lock Total Lock casters lock the wheel and swivel mechanism when pressing down on the tab WARNING LOCK CASTERS AT ALL TIMES EXCEPT WHEN MOVING TRANSPORTING CHAIR Wheel Lock cas...

Страница 10: ...TENDANT POSITION Attendant should be positioned on the RIGHT or LEFT side of chair CHAIRS WITH MANUAL ADJUSTMENT 1 Pull up on the back to to return to upright position 2 Attendant can use one hand to...

Страница 11: ...the chair place the chair into the fully reclined posi tion SEE Recline Chair From Attendant Position pg 9 2 Once chair is fully reclined attendant can push down on the rear of Trendelenburg lever A...

Страница 12: ...y engaged 180 SWING ARM OPTION This chair option provides swing arms that pivot up to 180 When both arms are pivoted fully back chair width is reduced to allow the chair to be more easily transported...

Страница 13: ...g 11 Item 2 WARNING Do NOT leave swing arm open after occupant is transferred to chair When closing swing arm make sure occupants extremities are clear of swing arm When closing swing arm make sure an...

Страница 14: ...2 TO LOWER TABLE Grasp table at the center or on both sides raise and pivot down in one movement PIVOT TABLE TO POSITION THE PIVOT TABLE 1 Loosen the adjustment knob A and swing away or place in the l...

Страница 15: ...ne mechanism when operating chair 1 2 1 2 RETURN TO THE SEATED POSITION CHAIRS WITH MANUAL ADJUSTMENT 1 To return the back to the full upright position grasp chair arms with both hands and pull body f...

Страница 16: ...sity 5X Alternating Upper Lower Back High Intensity 6X MASSAGE OFF Massage will automatically shut off after approximately 15 minutes Timer resets each time switch is pressed CLEANING With system disc...

Страница 17: ...amp cloth on a regular basis especially where skin hair make contact with upholstery Avoid harsh detergents that could dam age the upholstery or finish of your recliner If the furnishing is disinfecte...

Страница 18: ...late and Sidetables Maximum Weight Capacity 350 lbs VERO CARE CLINER SPECIFICATIONS VERO CARE CLINER Specifications VERO XL CARE CLINER Specifications Seat Height 21 to Foot Plate 18 Seat Width arm to...

Страница 19: ...RIGHT or BOTH sides Premium Style Side Table Available on LEFT RIGHT or BOTH sides Also available with Wood Finish Standard Side Table Available on LEFT RIGHT or BOTH sides Also available with Wood F...

Страница 20: ...20 VERO CARE CLINER OPTIONS Pedestal Feet Not Compatible with the Foot Plate Option 3 Caster Urethane Arm Not Compatible with the Foot Plate Option Arm Rest Covers Left and right available for all tab...

Страница 21: ...tion of the Armrest cover over the rear of the arm 5 For Premium Table you will need to release the table slightly to allow space to tuck the apron into the gap Standard Table will have enough room in...

Страница 22: ...ers mechanisms or related parts that are covered under above warranties Winco Mfg LLC shall not be liable for any labor shipping or any other costs incurred as a result of or in conjunction with a war...

Отзывы: