SAFETY

IMPORTANT SAFETY INSTRUCTIONS

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

SAFETY DEFINITIONS

DANGER

Indicates an imminently hazardous situation 

which, if not avoided, will result in death or 

serious injury. 

WARNING

Indicates a potentially hazardous situation 

which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury. It may also be used to alert 

against unsafe practices.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to the 

State of California to cause cancer, birth defects or other 

reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

DANGER: ELECTRICAL SHOCK 

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated by a 

responsible person.

 

A. Do not allow anyone to operate the generator 

   without 

proper 

instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or 

   snow.

 

E. Use only three-pronged grounded receptacles 

   and 

extension 

cords.

 

F. Be sure the unit is properly grounded for your 

   application.

DANGER: DEADLY EXHAUST GAS

Exhaust fumes from any gasoline engine contain carbon 

monoxide, an invisible, odorless and deadly gas that must 

be mixed with fresh air.

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached 

   garages

 

C. Never operate the unit in such a way as to allow 

      exhaust gases to seep back into closed rooms 

      (i.e. through windows, walls, floors).

WARNING: FIRE HAZARD

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

 

C. Do not smoke or use open flame near the 

      generator set or fuel tank.

 

D. Keep a fire extinguisher nearby and know its 

      proper use. Fire extinguishers rated ABC by 

   NFPA 

are 

appropriate.

 

E. Store fuel only in an approved container, and 

      only in a well ventilated area.

 

F. Follow local codes for closeness to combustible 

   material.

CAUTION: PERSONAL INJURY

The muffler becomes very hot during operation and for a 

period after the unit has been turned off. Do not touch the 

muffler until it has completely cooled off.

CAUTION: NOISE HAZARD

Excessive noise is not only tiring, but continual exposure 

can lead to loss of hearing.

 

A. Use hearing protection when working around 

      this equipment for long periods of time.

 

B. Keep your neighbors in mind when using this 

   equipment.

CAUTION

Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that 

   create 

      slippery conditions around the unit.

 

B. Remove any rags or other materials that could 

      create a potential fire hazard.

 

C. Carefully clean up any gas or oil spills before 

   starting 

the 

unit.

CAUTION

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or 

      receptacle panels while the engine is running.

 

D. Use extreme caution when working on electrical 

      components. High output voltage from this 

      equipment can cause serious injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, 

      and engine parts. They can cause severe burns 

   instantly.

 

F. The use of the engine-generator set must comply 

      with all national, state, and local codes.

Содержание PSS8B2F

Страница 1: ...o contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHA...

Страница 2: ...WITCH ENGINE GENERATOR SET ENGINE MAINTENANCE MAINTENANCE SCHEDULE TROUBLESHOOTING 22 OUTLINE DRAWING 23 PAD LAYOUT DRAWING 24 AC WIRING SCHEMATIC 24 AC AND DC GENERATOR SCHEMATIC 25 SOLAR CONTROL PAN...

Страница 3: ...t must be mixed with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back...

Страница 4: ...er option derate 30 and note the circuit breaker derates to 25 Amp FUEL CONSUMPTION Natural Gas 1000 BTU FT LP Vapor 2520 BTU FT CF HR 132 63 BTU HR 132 000 158 760 GAL HR N A 1 6 Based on full load o...

Страница 5: ...ment The ATS also contains the power failure sensing circuitry necessary to start and stop the engine generator set The transfer switch is also equipped standard with a 3 second start delay and a 15 s...

Страница 6: ...crankcase the first time use the dipstick A in following image to ensure that you do not over fill the crankcase The full oil level mark on the dipstick is depicted in the following image as B Oil is...

Страница 7: ...satisfactory system installation The information in this manual is offered only as a guide to finalizing your installation plans WARNING PERSONAL INJURY The enclosures on these units can become very...

Страница 8: ...rimary to the low pressure regulator Consult your local fuel supplier for your exact requirements The appropriate line size from the following table is then installed from the low pressure regulator t...

Страница 9: ...Natural gas Ref 2 3 4 Unit off Line PSI 7 11 in 4 6 oz 7 11 in 4 6 oz Starting Line PSI 7 11 in 4 6 oz 7 11 in 4 6 oz No load Line PSI 7 11 in 4 6 oz 7 11 in 4 6 oz Full load Line PSI 7 11 in 4 6 oz...

Страница 10: ...sh off immediately with water 3 If electrolyte contacts the eyes flush immediately and thoroughly with water Seek immediate medical attention 4 Spilled electrolyte is to be washed down with an acid ne...

Страница 11: ...be fused for 15 Amps Terminal block connections have been provided in the customer connection area of the engine generator set See following diagram NOTICE The battery tender is not intended to recha...

Страница 12: ...als L3 L7 The neutral leads from all three locations are connected to the isolated terminal lugs on the sidewall of the cabinet This terminal block is labeled NEUTRAL and the terminal lugs are mounted...

Страница 13: ...through 9 These terminals will accept 22 14 AWG stranded wire It is recommended that you use 16 AWG for distances up to 200 feet You need to run two 2 wires from the engine generator set to the transf...

Страница 14: ...y Deep Sea Electronics Model 3110 is used on this generator set See following picture and look for more information stated within this manual MANUAL OPERATION Press and release the red Stop Reset butt...

Страница 15: ...hanging the exercise without a load will be discussed later Be sure that conditions are safe to do this operation BYPASS TIME DELAY Use this button to cancel the active time delay or exercise period s...

Страница 16: ...art and run the exerciser must be reset after the power is restored The ASCO 185 has settings that can be changed for various applications The dipswitch options are explained in the ASCO 185 Operator...

Страница 17: ...17 60706 211 J SEQUENCE OF OPERATION UTILITY FAILURE...

Страница 18: ...Auxiliary inputs can be user configured and will display he message as written by the user Fail to Start The engine has not fired after the preset number of start attempts Fail to Stop The module has...

Страница 19: ...The fault must be removed and the Stop Reset button pressed to reset the module The icon will appear flashing in the display MODULE DISPLAY TIMER ICON When the module is controlling the engine startin...

Страница 20: ...il level must always be checked before the engine is started Refer to page 7 of this manual for instructions on checking the oil level Take care to remove any dirt or debris from around the oil plug b...

Страница 21: ...ked up engine generator set 9 Defective starter fuel solenoid relays ENGINE CRANKS BUT WILL NOT START 1 Improper fuel pressure being delivered to unit 2 Fuel supply shut off 3 Fuel supply empty 4 Defe...

Страница 22: ...22 60706 211 J 36 50 28 00 29 75 36 00 27 375 28 375 OUTLINE DRAWING...

Страница 23: ...23 60706 211 J PAD LAYOUT DRAWING 11075 00 20 60706 211 ENGINE GENERATOR SET PAD LAYOUT...

Страница 24: ...24 60706 211 J AC WIRING SCHEMATIC...

Страница 25: ...25 60706 211 J 11075 00 22 60706 211 AC AND DC GENERATOR SCHEMATIC AC AND DC GENERATOR SCHEMATIC...

Страница 26: ...26 60706 211 J EXTERNAL RECEPTACLE ASSEMBLY IF EQUIPPED SOLAR CONTROL PANEL IF EQUIPPED...

Страница 27: ...27 60706 211 J SOLAR PANEL ASSEMBLY IF EQUIPPED...

Страница 28: ...does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WINCO does not warrant engines Engines a...

Отзывы: