10
60706-229/F
Two regulator system (LP vapor only)
Ref#
1
2
3
4
Unit off
Line PSI
10-15 lbs
7-11 in
4-6 oz
7-11 in
4-6 oz
Starting
Line PSI
10-15 lbs
7-11 in
4-6 oz
7-11 in
4-6 oz
No load
Line PSI
10-15 lbs
7-11 in
4-6 oz
7-11 in
4-6 oz
Full load
Line PSI
10-15 lbs
7-11 in
4-6 oz
7-11 in
4-6 oz
Natural gas
Ref#
2
3
4
Unit off
2 PSI
7-11 in
4-6 oz
7-11 in
4-6 oz
Starting
2 PSI
7-11 in
4-6 oz
7-11 in
4-6 oz
No load
2 PSI
7-11 in
4-6 oz
7-11 in
4-6 oz
Full load
2 PSI
7-11 in
4-6 oz
7-11 in
4-6 oz
NG/LP FUEL CONVERSION
These generator sets are factory tested on NG and will
require no modifications for normal operation on NG. The
carburetion system has been preset and anti-tamper plugs
have been installed in the carburetor as required by the
EPA.
To make a fuel conversion you will have to first remove
the left side door. Looking down and to your left, you
will see decal and a plug. Remove the plastic plug with a
screwdriver. Using a 5mm or 3/16” hex allen wrench, turn
LEFT about 1/4 turn until you feel a click and it will stop
turning.
No other modifications to the unit are necessary. To switch
from LP to NG, you turn the selector to the right (NG)
position.
Содержание PSS20B2W/C
Страница 19: ...19 60706 229 F ...
Страница 24: ...24 60706 229 F OUTLINE DRAWING ...
Страница 25: ...25 60706 229 F PAD LAYOUT 60706 229 23 12270 01 60706 229 ET A ENGINE GENERATOR SET PAD LAYOUT ...
Страница 26: ...26 60706 229 F AC AND DC GENERATOR SCHEMATIC ...
Страница 27: ...27 60706 229 F AC WIRING SCHEMATIC PSS20 3 A PSS20 17 A PSS20 18 A PSS20 4 A ...