background image

28

OPM-145/D

WINCO Inc. has been engineering and manufacturing high quality generators since 1927. WINCO Inc. warrants to the original owner that the purchased 

product is free from defects in materials and/or workmanship for the period of time outlined below. If the product should prove defective within the time period 

outlined below, it will be repaired, adjusted or replaced at the option of WINCO Inc., provided that the product, upon inspection by an authorized WINCO Inc. 

service center, has been found to have been properly installed, maintained and operated in accordance with WINCO Inc.’s Installation and Operating Manuals, 

engine manufacturer installation and operation guidelines, and National and local code. This limited warranty is not valid or enforceable unless:

 

1. All supporting product maintenance records are kept on file and made available upon request from WINCO Inc. 

 

2. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and returned to 

 

  WINCO Inc. within 30 days of start-up. 

 

3. The product is routinely exercised in accordance with operating instructions. This warranty does not apply to malfunctions caused by 

 

  physical damage, misuse, improper installation, repair or service by unauthorized persons; or normal wear and tear. The warranty is 

 

  not assignable.

Prime WINCO Inc. Product Warranty Period:

 

• Engine generator set: Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours (whichever occurs first).

 

• Accessories (installed on the product or shipped loose): Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours 

 

  (whichever occurs first).

Standby WINCO Inc. Product  Warranty Period:

 

• Engine generator set: Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours (whichever occurs first).

 

• Accessories (installed on the product or shipped loose): Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours 

 

  (whichever occurs first).

The start of the warranty period can be adjusted to the date of unit start-up (limited up to 180 days from invoice date) provided that the following information is 

provided to WINCO Inc. at the time of start-up: 

 

  1. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and returned to 

 

    WINCO Inc. within 30 days of start-up. 

 

  2. Some engines may require revalidation after long-term storage. The engine revalidation process if included in the manual must be 

 

  followed.

To obtain warranty service: 

 

Contact your nearest authorized WINCO Inc. service center. For assistance in locating your nearest authorized service center, contact WINCO 

 

Inc.’s Service Department.

Warranty service may be performed by an authorized WINCO Inc. service center only. Service work performed by unauthorized persons will void all warranties.

WINCO Inc. shall not be liable for any claim in an amount greater than the purchase price of the product. In no event shall WINCO Inc. be held liable for any 

special, indirect, consequential or liquidated damages.

WINCO Inc. shall not be liable for any claim that requires replacement of engine, part, or component of the product that is no longer manufactured or available. 

Additionally, WINCO Inc. will not be liable for any engine replacement that may require an emissions tier-level change.

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, OR 

OTHERWISE CREATED UNDER THE UNIFORM COMMERCIAL CODE, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, OR WARRANTIES 

OF FITNESS FOR A PARTICULAR PURPOSE.

The following items and/or circumstances are excluded from this limited warranty:

 

• Engine starting batteries: The battery manufacturers’ warranty applies. Consult your local battery supplier for warranty service. 

 

• Fuel system and/or governing system adjustments performed during or after start-up.

 

• Normal maintenance items: Consumable items such as belts, filters and hoses.

 

• Damage caused by over-loading the generator and failure to adequately provide over-load protection.

 

• LP/NG fuel adjustments or conversion from one fuel to another.

 

• Any repeat or shop come-back repairs resulting from poor service work or improper diagnosis and testing. Replacement of parts as a trail-and-error 

 

  method of diagnosis will not be considered for warranty.

 

• Adjustments and tune–ups performed during start-up or thereafter. 

 

• Loose connections (electrical and mechanical) not found during start-up.

 

• All fluid level related items including low coolant not found during start-up or checked during regular maintenance intervals. 

 

• Equipment modifications made without the written consent of WINCO Inc. will void all warranties.

 

• Shipping damage of any type. All equipment is shipped F.O.B. factory and risk of loss transfers to the carrier once loaded for shipment. It is the 

 

  responsibility of the receiving party to sign for the receipt of, and note any shipping damage to the equipment. Freight damage claim filing is the 

 

  responsibility of the receiving party. In the rare event that damage occurs during shipment, WINCO Inc. will not warrant any damage to the unit 

 

  resulting from packaging material.

 

• Any special access fees, requirements or after hours scheduling to gain access to the equipment for warranty service purposes. 

 

• Rental generators used while warranty work is being performed.

 

• Damages caused by acts of nature, such as lightning, wind, flood, wild fires, or earthquake.

 

• Any damage due to situations beyond the control of the manufacturing and/or workmanship of the product. 

 

• Use of non-protected steel enclosure within 25 miles of the coast.

 

• Damage caused by improper installation or failure to provide adequate ventilation.

 

• Misapplication of the equipment such as usage outside the original design parameters as stated on the nameplate of the equipment. 

 

• Equipment purchased at the standby rating that is being used in a prime power application(s).

 

• Diesel engine “Wet Stacking” due to lightly loaded diesel engines.

 

• Travel time or service calls unless given written authorization by WINCO Inc.

ENGINE GENERATOR SET 

LIMITED WARRANTY

WINCO INC. • 225 S. CORDOVA AVE • LE CENTER, MN  56057 • 507-357-6821

Содержание DR12I4-03

Страница 1: ...ed to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE...

Страница 2: ...R CHANGING AIR FILTER DRAINING WATER SEPARATOR CLEANING WATER SEPARATOR ADJUSTING THE GOVERNOR STORAGE RETURNING ENGINE TO SERVICE MAINTENANCE SCHEDULE TROUBLE SHOOTING TABLES 23 WIRING SIZE TABLE 24...

Страница 3: ...e explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator set or fuel tank D Keep a...

Страница 4: ...16 Hertz 60 60 60 60 ENGINE Model ISUZU 3CE1 Starting System 12 Volt Fuel ASTM D 975 1D OR 2D Oil Type See Lubrication section in this manual Oil Capacity 7 Quarts Cooling System 50 50 mix See engine...

Страница 5: ...y records Several of the major components also have their own individual data plates providing additional information to document build data for warranty and replacements parts Be sure to have the mai...

Страница 6: ...olts 4 Unit can now be lifted from shipping rails LIFTING THE GENERATOR SET NOTICE PERSONAL INJURY To prevent injury to persons or equipment observe the following guidelines when lifting the generator...

Страница 7: ...to a solid base The engine generator is mounted on channels which are attached with special shock mounts to the main frame This allows the engine generator free movement without affecting the base or...

Страница 8: ...potential for contact with people is controlled Exhaust can enter buildings through windows ventilation systems and other openings if proper precautions are not followed The exhaust must be isolated...

Страница 9: ...Remove watches rings and other metal objects 2 Use tools with insulated handles 3 Check both the battery cable ends and the battery posts to be sure they are free of corrosion 4 Always connect the bat...

Страница 10: ...recharge the battery before attempting to start the unit Boost jump starting this unit improperly will result in PERMANENT DAMAGE TO THE ENGINE CONTROL MODULE ECM BATTERY CHARGER BLOCK HEATER BATTERY...

Страница 11: ...to 200 in lbs D 120V GFCI CIRCUIT TERMINAL BLOCK These terminals are rated for 20 Amps and will handle wire sizes 4 AWG to 18AWG They should be torqued to 16 in lbs This circuit must be fed from a fus...

Страница 12: ...5 The ports are wired onto the back of the DSE7310 In order to finalize communication the program will need to be adjusted using the free DSE configuration software to enable the commutation Contact W...

Страница 13: ...SCO 300 UL SWITCH When Normal Source Fails Terminals On Transfer Switch Contact Closes TB1 and TB2 Contact Opens TB1 and TB3 Engine start and auxiliary circuit terminal block TB located on 3ATS 3NTS t...

Страница 14: ...il and keeping the crankcase full cannot be over emphasized Failure to use the proper oil and keep the crankcase properly filled will cause excessive engine wear and shorten its useful life WINCO reco...

Страница 15: ...The small LED light next to it should come on Note There is no start delay in this mode of operation 2 Press and release the green START ENGINE button The DSE 7310 will send two signals to the engine...

Страница 16: ...start up it is most likely a false warning light Simply reset the ATS to start over Once you have completed testing of the ATS be sure you ALWAYS leave the system in the standby mode unless servicing...

Страница 17: ...be changed VOLTS To adjust generator output voltage Clockwise to increase voltage STABILITY To prevent voltage hunting Clockwise to increase the dampening effect UFRO Under Frequency Roll Off Termina...

Страница 18: ...als on lubricant and filter changes may need to be shortened An oil quality testing program can also provide early warnings or oil degradation Efforts may need to be made to reduce the amount of dust...

Страница 19: ...drained close the valve 5 Top off through the filler port using lubricant oil with the suitable oil table in the LUBRICATION section of this manual 6 Use the dip stick to ensure the level of oil does...

Страница 20: ...aminants Then reinstall and tighten the drain plug or close the drain valve in the radiator Reinstall and tighten the engine block drain plug 5 Fill radiator and engine with engine coolant CLEANING RA...

Страница 21: ...4 Replace the element with a new one if the element is damaged excessively dirty or oily 5 Clean inside of the air cleaner cover 6 Reinstall the element into the air cleaner case 4 Note If there is a...

Страница 22: ...e leaving the fuel system shut off so the engine will not start for 15 seconds Then pause for 30 seconds Repeat the procedure until you have cranked the engine for a total of one minute This will circ...

Страница 23: ...fuel solenoid Defective engine harness Improper battery voltage to fuel pump or fuel solenoid Engine starts then stops and alarm light comes on Engine oil pressure is low Engine has high water temper...

Страница 24: ...THHW THW 2 XHH XHHW XHHW 2 ZW 2 SIZE AWG OR KCMIL Wire Type RHW THHW THW THWN XHHW USE Wire Type TBS SA SIS THHN THW 2 THWN 2 RHH RHW 2 USE 2 XHH XHHW XHHW 2 ZW 2 50 65 85 100 115 130 150 175 200 230...

Страница 25: ...725 127 620 02 6 20 48 3 7 8 9 2 35 6685 1 22 17 7 03 5 785 6 7 6 6 1 5 81 76 3 785 8 1 2 22 17 021 725 1 785 6 5 237 21 27 1 8 62 12 7 1250 26 9 9 5 9 6 216 5 9 51 6 5 37 21 7 33 3 25 1 7 2 5 3 83 7...

Страница 26: ...5 7 50 1 2 6 211 725 211 725 66 86 86 86 86 86 36 1 2 8 1387 20021 6 5 1 1 6 5 1 1 1 1 1 36 32 5 6 7 66 0 5 1 6723 6 7 66 8 6 7 21 6 7 9 5 92 7 8670 17 5 267 7 9 5 1 855 17 66 7 50 1 2 803 56 6 2 1 29...

Страница 27: ...27 OPM 145 D THREE PHASE AC WIRE HIGH AND LOW WYE THREE PHASE AC WIRING DELTA SINGLE PHASE 311 WINDING WIRING DIAGRAMS...

Страница 28: ...d liable for any special indirect consequential or liquidated damages WINCO Inc shall not be liable for any claim that requires replacement of engine part or component of the product that is no longer...

Отзывы: