15.4.4 Application
Note
z
TAR
,
CAR
,
TLR
,
CLR
are all BCD counter, but
FCR
is not a BCD counter.
z
Programmer must be aware that the RTC block do not check whether the loaded value are
reasonable. For example, Load
CLR
as 201a (year), 13 (month), 00 (day), or
CLR
does not
match with
DWR
, etc.
z
Reset state :
Register
Value
Describtion
AER
0
RTC read/write disable
CLR
05 , 1 ,1
2005-1-1
TLR
00 00 00
00 hr, 00 min, 00 sec
CAR
00,00,00
2000-0-0
TAR
00,00,00
00 hr, 00 min, 00 sec
TSSR
1
24 hr mode
DWR 6
Saturday
RIER
0
Time Tick Interrupt and counter
disable
RTC Alarm Interrupt disable
RIIR
0
Time tick interrupt has never
occurred
Alarm interrupt has never occurred
LIR
0
Indicate that this year is not a leap
year
TTR
0
Disable
z
FCR Calibration :
A (a)
FCR
integer : look up the below table.
Integer part of
detected value
FCR[11:8]
Integer part of
detected value
FCR[11:8]
32776 1111 32768 0111
32775 1110 32767 0110
32774 1101 32766 0101
32773 1100 32765 0100
32772 1011 32764 0011
32771 1010 32763 0010
32770 1001 32762 0001
32769 1000 32761 0000