W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 56 -
T0
T1
T2
T13
T14
T21
T24
T25
T26
T27
T28
CK#
CK
Command
NOP
Address
READ
NOP
ACT
PRE
NOP
NOP
Bank a,
Col n
DQS, DQS#
DQ
NOP
NOP
NOP
T29
T30
T31
T35
NOP
Bank a,
(or all)
NOP
NOP
NOP
NOP
Dout
n
Dout
n+1
Dout
n+2
Dout
n+3
Dout
n+4
Dout
n+5
Dout
n+6
Dout
n+7
CL = 14
Dout
n
Dout
n+1
Dout
n+2
Dout
n+3
DQS, DQS#
DQ
BL4 Operation:
BL8 Operation:
t
RP
AL = CL - 2 =12
T34
NOP
t
RTP
Bank a,
Row b
TRANSITIONING DATA
DON'T CARE
NOTES:
1. RL = 26 (CL = 14, AL = CL - 2)
2. Dout n = data-out from column n.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. The example assumes t
RAS.MIN
is satisfied at Precharge command time (T21) and that t
RC.MIN
is satisfied at the next Active command time (T35).
TIME BREAK
RL = 26
Figure 39
– READ to PRECHARGE (RL = 26, AL = CL-2, CL = 14, t