12
Operation, Commande, Operación
Adjustment continuous flow (2 s – 10 min)
The continuous flow time can be adjusted in normal operation mode at any time:
1x.. 5 s
Push the button on the left side of the tap for 5 s - LED lights for 2
seconds then and water flow stops.
If you put your finger from the button within these 2 seconds, the
water flow will be released and setting time for continuous flow
starts to count - so the continuous flow can be adjusted individually:
push the button again after desired time (f.ex. after 20 s) and the con-
tinuous flow is adjusted for this time from now on (new continuous
flow time is f.ex. 20 s). If you don´t push the button again, the water
flows for the maximum continuous flow time of 10 min and the new
adjusted continuous flow time is 10 min.
Reset to pre-adjusted factory settings
Seperate the tap from power supply for min. 3 minutes. (Remove the battery)
Then insert the battery again and push the button at the same time. The tap is adjusted to the factory
settings again now - LED lights for 4 s.
All adjustments, which you made up to now at continuous flow, automatic flushing stop time
and active range, are reset!
1
Change the battery
If the battery gets empty, the LED starts flashing.
Open screw with socket wrench
(SW 2) by turning 4 times, turn
electronic unit and take it off.
SW 2mm
Remove the battery.
Insert the new battery and
mount electronic unit again.
F
E
GB