Setting mode (1. to adjust programs / 2. active range / 3. autom. flushing stop)
Activating the setting mode:
push the small button on the left side of the tap for 5 seconds and make a close-range reflex at the
same time (move your hand with a distance of about 2 centimeters in front of the sensor window)
+
The control confirms setting mode by 5 quick flashes and water flow stops.
1. program adjusting
Now the
program adjusting
mode is activated (1-5 adjustable)
Push the button once (flashing once)
= program 1 chosen
Push the button twice (flashing twice)
= program 2 chosen
Push the button three times (flashing three times) = program 3 chosen
...
Choose the required program - after 10 s the control confirms the chosen program by 5 quick flashes.
If you don´t push the button and so don´t chose a program, the present program remain adjusted and
the control confirms finishing the program adjusting mode by 5 quick flashes after 10 s
2. active range
Afterwards you are in the active range mode:
Move your hand in front of the sensor window at the desired distance for the active range and push
the button (adjustable from 10 – 35 cm). The new active range is saved now and the control confirms
by 5 quick flashes.
If you don´t want to change the active range wait for 10 s – then the control confirms finishing the
active range mode by 5 quick flashes.
3. automatic flushing stop
Afterwards you are in the time setting mode for automatic flushing stop (adjustable from 1 – 5 min)
Push the button once (flashing once)
= flushing stop after 1 min. adjusted
Push the button twice (flashing twice)
= flushing stop after 2 min. adjusted
Push the button three times (flashing three times) = flushing stop after 3 min. adjusted
…
Then wait for 10 s and the control confirms activating the new flushing stop time by 10 flashes.
If you don´t want to change the flushing stop time don´t push the button and wait for 10 s – then the
control confirms finishing the time setting mode for automatic flushing stop by 10 flashes.
Then the control will change into normal function again.