Shower control
WimTec OCEAN P6 with thermal disinfection
33
EN
PROOF P6 with thermal disinfection
Description of the functions
Shower monitoring
This function causes the
infrared sensor to monitor the
sensor range during thermal
disinfection.
Safety flow arrest
The water flow is immediately
cut off if you approach the
panel.
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
Protection from scalding:
DIP switch 5
This function serves to monitor the sensor range during thermal
disinfection.
Thermal disinfection may be accidently aborted if dense steam
forms in front of the shower fitting. If this happens, disable the
function to protect against exposure to scalding water.
DIP switch 5 ON = Function to protect against exposure to scalding
water enabled (default setting).
DIP switch 5 OFF = Function to protect against exposure to scalding
water disabled.
1 2 3 4 5 6
ON
OFF
Halbautomatik:
Vollautomatik:
Manuell:
Warmlauf:
ON
OFF
1 2 3
4
5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
Reinigungsstopp:
ON
OFF
1 2 3 4
5
6
Hygienespülung:
ON
OFF
1 2 3 4 5
6
If possible, this safety
function should always
be activated.
!