Shower control
WimTec PROOF P6
35
EN
PROOF P6
Stagnation rinse:
DIP switch 6
Description of the functions
Serves to remove stagnant water that accumulates during longer periods of disuse.
DIP switch 6 ON = Stagnation rinse function enabled.
DIP switch 6 OFF = Stagnation rinse function disabled (default setting).
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
3
-
48
h
10
s
1 2 3 4 5 6
ON
OFF
Halbautomatik:
Vollautomatik:
Manuell:
Warmlauf:
ON
OFF
1 2 3
4
5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
Reinigungsstopp:
ON
OFF
1 2 3 4
5
6
Hygienespülung:
ON
OFF
1 2 3 4 5
6
60 cm
60 cm
60 cm
60 cm
50 cm
Time interval
Can be set from 3–48 h at the
interval control (see p. 23).
Automatic stagnation rinse
If the fitting has not been used
for the set period, the stagnati-
on rinse operation is automati-
cally executed for 10 s.
Safety
If the cleaning stop function is
enabled, the stagnation rinse
function will only start 2 min
after the cleaning stop function
has been disabled.