Wilo Wilo-CronoBloc-BL Скачать руководство пользователя страница 7

English

22

WILO SE 11/2013

Installation and operating instructions

1

General

About this document

The language of the original operating instructions is German. All 
other languages of these instructions are translations of the original 
operating instructions.

These installation and operating instructions are an integral part of 
the product. They must be kept readily available at the place where 
the product is installed. Strict adherence to these instructions is a 
precondition for the proper use and correct operation of the product.

These installation and operating instructions correspond to the rele-
vant version of the product and the underlying safety standards valid 
at the time of going to print.

EC declaration of conformity

A copy of the EC declaration of conformity is a component of these 
operating instructions.

If a technical modification is made on the designs named there with-
out our agreement, this declaration loses its validity.

2

Safety

These operating instructions contain basic information which must 
be adhered to during installation and operation. For this reason, these 
operating instructions must, without fail, be read by the service tech-
nician and the responsible operator before installation and commis-
sioning.

It is not only the general safety instructions listed under the main 
point “safety” that must be adhered to but also the special safety 
instructions with danger symbols included under the following main 
points.

2.1

Indication of instructions in the 
operating instructions

Symbols

General danger symbol

Danger due to electrical voltage

NOTE

Signal words

DANGER!
Acutely dangerous situation
Non-observance results in death or the most serious of injuries.

WARNING!
The user can suffer (serious) injuries. 'Warning' implies that (seri-
ous) injury to persons is probable if this information is disregarded.

CAUTION!
There is a risk of damaging the product/unit. 'Caution' implies that 
damage to the product is likely if this information is disregarded.

NOTE
Useful information on handling the product. It draws attention to 
possible problems.

Содержание Wilo-CronoBloc-BL

Страница 1: ...Twin DL Wilo CronoBloc BL Pioneering for You 2 136 319 Ed 02 2013 11 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbou...

Страница 2: ......

Страница 3: ...Fig 1 IL Fig 2 DL...

Страница 4: ...Fig 3 BL...

Страница 5: ...de Einbau und Betriebsanleitung 3 en Installation and operating instructions 22 fr Notice de montage et de mise en service 41 nl Inbouw en bedieningsvoorschriften 60...

Страница 6: ...Shipping 24 3 2 Attachment 24 4 Intended use 25 5 Product information 25 5 1 Type key 25 5 2 Technical data 26 5 3 Scope of delivery 27 5 4 Accessories 27 6 Description and function 27 6 1 Description...

Страница 7: ...oses its validity 2 Safety These operating instructions contain basic information which must be adhered to during installation and operation For this reason these operating instructions must without f...

Страница 8: ...lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Childrenshould be supervised to ensur...

Страница 9: ...proper transport can lead to personal injury The pump must be transported using approved load bearing equip ment This is to be attached to the pump flanges and if necessary to the outer motor diameter...

Страница 10: ...on is only possible with the corre sponding special versions motor with standby heating and fan cover protective roof see section 7 3 on page 32 CAUTION Risk of damage Impermissible substances in the...

Страница 11: ...class F Protection class 55 Pipe and pressure measurement connec tions Flange PN 16 in accordance with DIN EN 1092 2 with pressure measure ment connections Rp 1 8 in accordance with DIN 3858 Approved...

Страница 12: ...p operation IL The pump housing has an INLINE construction i e the flanges on the suction and pressure sides lie along a centre line Fig 6 All pump housings are provided with a pump base Mounting on a...

Страница 13: ...rallel operation 0 55 51 54 54 57 0 5 51 54 60 63 1 1 53 56 60 63 1 5 55 58 67 70 2 2 59 62 67 70 3 59 62 67 70 4 59 62 67 70 5 5 63 66 71 74 7 5 63 66 71 74 11 65 68 74 77 15 65 68 74 77 18 5 71 74 7...

Страница 14: ...y 10 of the maximum flow rate must be ensured at all times 7 1 Installation The motor terminal box must not face downward If necessary the motor or motor impeller unit can be rotated once the hexagon...

Страница 15: ...r support is not necessary Only the installation position with vertical motor shaft is intended for a motor power 15 kW BL series monobloc pumps are to be mounted on a sufficiently strong base or moun...

Страница 16: ...Position the threaded cable connec tion or lay the cables accordingly to ensure that no drips can run into the module Non assigned threaded cable connections must remain sealed with the plugs provided...

Страница 17: ...used to protect the motor windings against con densation water inside the motor The standby heating is connected to the terminals HE HE in the ter minal boxes connection voltage 1 230 V 50 Hz NOTE Th...

Страница 18: ...en opening the vent screw WARNING Risk of burns or freezing to the pump when body parts come into contact with the pump Depending on the pump or system operating conditions fluid tem perature the enti...

Страница 19: ...be reinstalled WARNING Risk of injury due to the weight of the pump The pump itself and the parts of pump can be extremely heavy Falling parts pose a risk of cuts crush injuries bruises or impacts wh...

Страница 20: ...3 Item 5 on the motor flange and lift the drive off the pump with suitable hoisting gear On BL pumps the adapter ring comes loose Fig 3 Item 8 By loosening the lantern fastening screws Fig 1 2 3 Item...

Страница 21: ...opening the vent screw Fig 1 2 3 Item 1 31 DANGER Risk of scalding Due to high fluid temperatures there is a risk of scalding If the fluid is hot allow it to cool down before performing any work NOTE...

Страница 22: ...m 10 Installation instructions Impeller Shaft M10 M12 M16 30 60 100 Pump housing Lantern M16 100 Tighten evenly and diagonally Lantern Motor M10 M12 M16 35 60 100 Coupling M6 10 9 M8 10 9 M10 10 9 M12...

Страница 23: ...o customer service or a spe cialised service centre and serviced if necessary Motor protection switch has triggered Throttle the pump to the rated volume flow on the pressure side Motor protection swi...

Страница 24: ...No Part Details No Part Details 1 Exchange set complete 1 1 Impeller set with 1 5 Coupling complete 1 11 Nut 2 Motor 1 12 Spring washer 3 Pump housing set with 1 13 Impeller 1 14 O ring 1 14 O ring 3...

Страница 25: ......

Страница 26: ......

Страница 27: ...chkeit Richtlinie 2004 108 EG Electromagnetic compatibility directive Directive compatibilit lectromagn tique Richtlinie energieverbrauchsrelevanter Produkte 2009 125 EG Energy related products direct...

Страница 28: ...dla produkt w zwi zanych z energi 2009 125 WE 2009 125 Pou it 50Hz t f zov induk n motory s klecov m rotorem jednostupJov vyhovuj po adavkQm na ekodesign dle na zen 640 2009 Stosowane elektryczne sil...

Страница 29: ...20 27442100 Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 Ireland WILO Ireland T 353 61 227566 Italy Borromeo Milano T 39 25538351 Kazakhstan WILO Central Asia 050002 Almaty T 7...

Страница 30: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: