English
26
WILO SE 11/2013
5.2
Technical data
When ordering spare parts be sure to state all the information given
on the pump and motor type plates.
Fluids
If water/glycol mixtures with up to 40% glycol (or fluids with a differ-
ent velocity to pure water) are used, the pump data must be corrected
to match the higher viscosity, regardless of the percentage mixture
relationship and the fluid temperature. The motor power must also be
adjusted if necessary.
• Only use mixtures with corrosion inhibitors. The respective manufac-
turer's instructions are to be observed.
• The fluid must be sediment-free.
• Wilo's approval must be obtained for use of other media.
NOTE
Always read and follow the material safety data sheet for the fluid
being pumped!
Property
Value
Remarks
Nominal speed
2900 or 1450 rpm
Nominal diameters DN
IL: 32 to 200 mm
DL: 32 to 200 mm
BL: 25 to 125 mm (pressure side)
Permissible min./max. fluid temperature
–20 °C to +140 °C
Max. ambient temperature
+ 40 °C
Max. admissible operating pressure
16 bar (version... -P4: 25 bar)
Insulation class
F
Protection class
55
Pipe and pressure measurement connec-
tions
Flange PN 16 in accordance with
DIN EN 1092-2 with pressure measure-
ment connections Rp 1/8 in accordance
with DIN 3858
Approved fluids
Heating water according to VDI 2035
Process water
Cooling/cold water
Water/glycol mixture up to 40 Vol.-%
Standard version
Standard version
Standard version
Standard version
Heat transfer oil
Special version or auxiliary equip-
ment (at additional charge)
Other fluids (on request)
Special version or auxiliary equip-
ment (at additional charge)
Electrical connection
3~400 V, 50 Hz
Standard version
3~230 V, 50 Hz
(to 3 kW inclusive)
Alternative application for stand-
ard version (no additional charge)
3~230 V, 50 Hz from 4 kW
Special version or auxiliary equip-
ment (at additional charge)
Special voltage/frequency
Pumps with motors with different volt-
ages or with other frequencies are
available on request.
Special version or auxiliary equip-
ment (at additional charge)
PTC thermistor sensor
–
Only for special version
Speed control, pole switchover
Control devices (Wilo CC system)
Pole switchover
Standard version
Only for special version
Explosion protection (EEx e, EEx de)
–
Special version or auxiliary equip-
ment (at additional charge)
Содержание Wilo-CronoBloc-BL
Страница 2: ......
Страница 3: ...Fig 1 IL Fig 2 DL...
Страница 4: ...Fig 3 BL...
Страница 25: ......
Страница 26: ......