Installation and operating instructions Wilo-IL/-DL/-BL

39

Spare parts table

Allocation of assemblies, see Fig. 1/2/3 

12

Disposal

Proper disposal and recycling of this product prevents damage to the 
environment and risks to personal health.

Proper disposal requires the drainage and cleaning and the disman-
tling of the pump unit.

Lubricants must be collected. The pump components are to be sepa-
rated according to material (metal, plastic, electronics).

1. Use public or private disposal organisations when disposing of all 

or part of the product.

2. For more information on proper disposal, please contact your local 

council or waste disposal office or the supplier from whom you 
obtained the product.

Subject to change without prior notice!

No.

Part

Details

No.

Part

Details

1

Exchange set 
(complete)

1.1

Impeller (set) with:

1.5

Coupling (complete)

1.11

Nut

2

Motor

1.12

Spring washer

3

Pump housing (set) 
with:

1.13

Impeller

1.14

O-ring

1.14

O-ring

3.1

Pump housing
(IL, DL, BL)

1.2

Mechanical shaft seal 
(set) with:

3.2

Stopper for pressure 
measurement connec-
tions

1.11

Nut

3.3

Switchover valve 

 DN 80 

(only DL pumps)

1.12

Spring washer

3.4

Switchover valve 

DN 100

(only DL pumps)

1.14

O-ring

4

Fastening screws for 
lantern/pump housing

1.21

Mechanical seal (com-
plete)

5

Fastening screws for 
motor/lantern

1.3

Lantern (set) with:

6

Nut for motor/lantern 
fixing

1.11

Nut

7

Washer for motor/lan-
tern fixing

1.12

Spring washer

8

Adapter ring 
(only BL pumps)

1.14

O-ring

9

Pump supporting feet 
for motor sizes 

  4 kW 

(only BL pumps)

1.31

Bleed valve

10

Forked spacer (Fig. 15)

1.32

Coupling protection

1.33

Lantern

1.4

Shaft (set) with:

1.11

Nut

1.12

Spring washer

1.14

O-ring

1.41

Shaft compl.

1.42

Snap ring

Содержание Wilo-CronoBloc-BL

Страница 1: ...Twin DL Wilo CronoBloc BL Pioneering for You 2 136 319 Ed 02 2013 11 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbou...

Страница 2: ......

Страница 3: ...Fig 1 IL Fig 2 DL...

Страница 4: ...Fig 3 BL...

Страница 5: ...de Einbau und Betriebsanleitung 3 en Installation and operating instructions 22 fr Notice de montage et de mise en service 41 nl Inbouw en bedieningsvoorschriften 60...

Страница 6: ...Shipping 24 3 2 Attachment 24 4 Intended use 25 5 Product information 25 5 1 Type key 25 5 2 Technical data 26 5 3 Scope of delivery 27 5 4 Accessories 27 6 Description and function 27 6 1 Description...

Страница 7: ...oses its validity 2 Safety These operating instructions contain basic information which must be adhered to during installation and operation For this reason these operating instructions must without f...

Страница 8: ...lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Childrenshould be supervised to ensur...

Страница 9: ...proper transport can lead to personal injury The pump must be transported using approved load bearing equip ment This is to be attached to the pump flanges and if necessary to the outer motor diameter...

Страница 10: ...on is only possible with the corre sponding special versions motor with standby heating and fan cover protective roof see section 7 3 on page 32 CAUTION Risk of damage Impermissible substances in the...

Страница 11: ...class F Protection class 55 Pipe and pressure measurement connec tions Flange PN 16 in accordance with DIN EN 1092 2 with pressure measure ment connections Rp 1 8 in accordance with DIN 3858 Approved...

Страница 12: ...p operation IL The pump housing has an INLINE construction i e the flanges on the suction and pressure sides lie along a centre line Fig 6 All pump housings are provided with a pump base Mounting on a...

Страница 13: ...rallel operation 0 55 51 54 54 57 0 5 51 54 60 63 1 1 53 56 60 63 1 5 55 58 67 70 2 2 59 62 67 70 3 59 62 67 70 4 59 62 67 70 5 5 63 66 71 74 7 5 63 66 71 74 11 65 68 74 77 15 65 68 74 77 18 5 71 74 7...

Страница 14: ...y 10 of the maximum flow rate must be ensured at all times 7 1 Installation The motor terminal box must not face downward If necessary the motor or motor impeller unit can be rotated once the hexagon...

Страница 15: ...r support is not necessary Only the installation position with vertical motor shaft is intended for a motor power 15 kW BL series monobloc pumps are to be mounted on a sufficiently strong base or moun...

Страница 16: ...Position the threaded cable connec tion or lay the cables accordingly to ensure that no drips can run into the module Non assigned threaded cable connections must remain sealed with the plugs provided...

Страница 17: ...used to protect the motor windings against con densation water inside the motor The standby heating is connected to the terminals HE HE in the ter minal boxes connection voltage 1 230 V 50 Hz NOTE Th...

Страница 18: ...en opening the vent screw WARNING Risk of burns or freezing to the pump when body parts come into contact with the pump Depending on the pump or system operating conditions fluid tem perature the enti...

Страница 19: ...be reinstalled WARNING Risk of injury due to the weight of the pump The pump itself and the parts of pump can be extremely heavy Falling parts pose a risk of cuts crush injuries bruises or impacts wh...

Страница 20: ...3 Item 5 on the motor flange and lift the drive off the pump with suitable hoisting gear On BL pumps the adapter ring comes loose Fig 3 Item 8 By loosening the lantern fastening screws Fig 1 2 3 Item...

Страница 21: ...opening the vent screw Fig 1 2 3 Item 1 31 DANGER Risk of scalding Due to high fluid temperatures there is a risk of scalding If the fluid is hot allow it to cool down before performing any work NOTE...

Страница 22: ...m 10 Installation instructions Impeller Shaft M10 M12 M16 30 60 100 Pump housing Lantern M16 100 Tighten evenly and diagonally Lantern Motor M10 M12 M16 35 60 100 Coupling M6 10 9 M8 10 9 M10 10 9 M12...

Страница 23: ...o customer service or a spe cialised service centre and serviced if necessary Motor protection switch has triggered Throttle the pump to the rated volume flow on the pressure side Motor protection swi...

Страница 24: ...No Part Details No Part Details 1 Exchange set complete 1 1 Impeller set with 1 5 Coupling complete 1 11 Nut 2 Motor 1 12 Spring washer 3 Pump housing set with 1 13 Impeller 1 14 O ring 1 14 O ring 3...

Страница 25: ......

Страница 26: ......

Страница 27: ...chkeit Richtlinie 2004 108 EG Electromagnetic compatibility directive Directive compatibilit lectromagn tique Richtlinie energieverbrauchsrelevanter Produkte 2009 125 EG Energy related products direct...

Страница 28: ...dla produkt w zwi zanych z energi 2009 125 WE 2009 125 Pou it 50Hz t f zov induk n motory s klecov m rotorem jednostupJov vyhovuj po adavkQm na ekodesign dle na zen 640 2009 Stosowane elektryczne sil...

Страница 29: ...20 27442100 Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 Ireland WILO Ireland T 353 61 227566 Italy Borromeo Milano T 39 25538351 Kazakhstan WILO Central Asia 050002 Almaty T 7...

Страница 30: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: