8 Faults, causes and remedies
If the fault cannot be remedied, please contact your local plumbing and heating specialist or WILO customer
services.
9 Spare parts
Available spare parts (see Fig. 4, 5):
1
Exchange set complete
1.1
Set impeller with
1.11
Nut
1.12
Plain washer
1.13
Impeller
1.14
O-ring
1.2
Set mechanical seal with
1.11
Nut
1.12
Plain washer
1.14
O-ring
1.21
Mechanical seal complete
2
Exchange set motor
2.1
Vent screw
3
Pumphousing complete with
1.14
O-ring
3.1
Pumphousing (IPL, DPL)
3.2
Plug for gauge tappings
3.3
Check flap
ⱕ
DN 80 (DPL-Pumps only)
3.4
Check flap
ⱖ
DN 100
(DPL-Pumps only)
4
Fixing-screws motorflange / pumphousing
(also within exchange set motor)
When ordering spare parts, please state spare part
numbers - descriptions and all data of pump and
motor name plate.
Technical modifications reserved!
Faults
Possible cause
Remedy
Pump does not start or fails to run
Pump chocked up
switch off power supply, take-off pump
head, remove obstruction; if motor blo-
cked, overhaul/exchange motor/pump
head
Loose terminals
tighten all terminals
Defect fuses
check fuses, change defect fuses
Faulty motor
call service
Tripped overload relay
throttle hydraulic flow rate down to
nominal at discharge side of pump
Incorrectly set trip relay
reset thermal overloads to name plate
FLC-value
Thermal overload are influenced by
excessive ambient temperature
reposition overload relay or protect by
thermal insulation
Tripped PTC-relay
check motor and fan cover for dirt/dust
accumulation and clean if necessary;
check ambient temperature and if
necessary, ensure an ambient tempera-
ture
ⱕ
40 °C by forced ventilation.
Pump runs at reduced
capacity
incorrect rotation
check direction of rotation, if necessary
Discharge valve throttled too far
slowly open isolating valve
Speed too low
correct wrong terminal bridging
(Y in lieu
⌬
)
Air in suction pipe
check and correct flange leakages,
eventually vent pipe section
Pump makes noise
insufficient inlet pressure
raise inlet pressure, ensure minimum
required inlet pressure at suction port,
check and if necessary clean suction-
side isolating valve and strainer
Faulty motor bearings
Arrange for pump to be inspected and, if
necessary, to be repaired by Wilo or
other authorized service.
Impeller scratches
Test the contact between lantern and
pumphousing. Clean it, if necessary.
Only original Wilo spare parts are to be
used to ensure the fault-free operation of
the pump.