background image

en

6

Installation and operating instructions • Wilo-Rexa FIT-S • Ed.01/2022-03

Comply with the requirements of the local
energy supply company.

Train personnel on how to make electrical
connections.

Train personnel on the options for switching
off the device.

Observe the technical information in these
installation and operating instructions as well
as on the rating plate.

Earth the device.

Observe provisions for connection to the
electrical switching system.

Comply with the specifications on electro-
magnetic compatibility when using electronic
start-up controllers (e.g. soft starter or fre-
quency converter). If required, take special
measures into account (e.g. shielded cables,
filters, etc.).

Replace defective connection cables. Contact
customer service.

2.5

Monitoring devices

The following monitoring devices must be
provided on-site:

Circuit breaker

The size and switching characteristics of the
circuit breakers must conform to the rated cur-
rent of the connected product. Observe local
regulations.

Motor protection switch

Make provision for an on-site motor protection
switch for devices without a plug! The minimum
requirement is a thermal relay/motor protection
switch with temperature compensation, differ-
ential triggering and anti-reactivation device in
accordance with the local regulations. In case of
sensitive mains, make provision for the installa-
tion on-site of other protective equipment (e.g.
overvoltage, undervoltage or phase failure relay,
etc.).

Residual-current device (RCD)

Install a residual-current device (RCD) in ac-
cordance with the regulations of the local en-
ergy supply company.

If people can come into contact with the
device and conductive fluids, install a resid-
ual-current device (RCD).

2.6

Fluids hazardous to health

Hazardous germs form in sewage or in stagnant
water. There is a danger of bacterial infections!

Wear protective equipment!

Clean and disinfect the product thoroughly
after removal!

Inform all persons about the pumped fluid and
the danger it poses!

2.7

Transport

Locally applicable laws and regulations on
work safety and accident prevention must be
complied with.

Always carry the product by the handle!

2.8

Use of lifting equipment

If lifting equipment (lifting device, crane, chain
hoist …) is used, observe the following points:

Wear a safety helmet according to EN 397!

Comply with local regulations on the use of
lifting equipment.

The technically correct use of the lifting
equipment is the operator’s responsibility!

Lifting gear

Use legally specified and approved lifting
gear.

Select lifting gear based on the attachment
point.

Attach lifting gear to the attachment point
according to local regulations.

Lifting equipment

Check it functions properly before use!

Sufficient bearing capacity.

Ensure stability during use.

Lifting operation

Do not jam the product when lifting and
lowering it.

Do not exceed the max. permissible bearing
capacity!

If necessary (e.g. blocked view), assign a
second person to coordinate.

No one should stand under suspended
loads!

Содержание Rexa FIT-S

Страница 1: ...Pioneering for You Wilo Rexa FIT S 6092602 Ed 01 2022 03 en Installation and operating instructions...

Страница 2: ...Rexa FIT S http qr wilo com 414 Rexa FIT https qr wilo com 771...

Страница 3: ...ials 9 5 3 Technical data 10 5 4 Type key 10 5 5 Scope of delivery 10 5 6 Accessories 10 6 Installation and electrical connection 10 6 1 Personnel qualifications 10 6 2 Installation types 10 6 3 Opera...

Страница 4: ...ent Non compliance with these instructions Improper use Incorrect storage or transport Incorrect installation or dismantling Insufficient maintenance Unauthorised repairs Inadequate construction site...

Страница 5: ...them during use of the product supervisor Persons with limited physical sensory or mental capacities Use of this product is pro hibited 2 3 Personal protective equipment The protective equipment spec...

Страница 6: ...quipment e g overvoltage undervoltage or phase failure relay etc Residual current device RCD Install a residual current device RCD in ac cordance with the regulations of the local en ergy supply compa...

Страница 7: ...et and pressure pipe Ensure minimum water submersion by using dry running protection Sound pressure level depends on several factors installation duty point etc Measure the current noise level under o...

Страница 8: ...ied to the transport company or the man ufacturer on the day of receipt of shipment Subsequently notified defects can no longer be asserted 3 2 Transport CAUTION Soaked packaging may tear The product...

Страница 9: ...contents e g sand gravel Intended use also includes compliance with this manual Any other use is regarded as non compliant with intended use 5 Product description 5 1 Description Fully submersible gri...

Страница 10: ...y for rated voltage P Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 5 5 Scope of delivery Pump Installation and operating instructions...

Страница 11: ...le length are sufficient for the selected installation type Installation of switchgear Observe information in the manufac turer s instructions IP class overflow proof potentially explos ive atmosphere...

Страница 12: ...ace If the pump is used at the same location for a longer period of time bolt the pump support foot to the floor This reduces vi brations and enables quiet operation 1 6 5 3 4 2 OFF S1 S2 S3 Fig 5 Por...

Страница 13: ...l relay motor protection switch with temperature compensation differential triggering and anti reactivation device in accordance with the local regulations In case of sensitive mains make provision fo...

Страница 14: ...protection to the rated current according to the rating plate Partial load operation Set the motor protection to 5 above the current measured at the duty point 6 5 6 2 Soft starter Full load Set the m...

Страница 15: ...nding on the fill level ON OFF Switch the pump on and off in operating mode HAND Pump with attached plug Single phase AC version 1 motor Insert the plug into the socket the pump is ready for operation...

Страница 16: ...rotect the pump from frost and ice Minimum fluid temperature 3 C 37 F 1 Switch off the pump 2 Secure the operating point against being switched on again by unauthorised persons e g lock main switch Th...

Страница 17: ...equipment to the attachment point on the pump 3 Lift the pump approximately 30 cm 10 in above the ground 4 Spray the pump with clean water from top to bottom 5 Guide the water jet inwards through the...

Страница 18: ...remain constant Slight fluctu ations depend on the characteristics of the fluid Power consump tion can provide an early indication of damage or malfunctions in the impeller bearings or motor which can...

Страница 19: ...customer service 8 Pour in operating fluid Rotate the pump until the opening points upwards Pour the operating fluid into the opening Comply with the specifications for the operating fluid type and qu...

Страница 20: ...Wet fastening screw with thread locking fluid and screw it into cutting head Tighten the fastening screw hand tight 7 Secure the cutting head Insert wedge between cutting head and cutting plate CAUTIO...

Страница 21: ...r cushion in the pipe system Vent the pipe system If air cushions occur frequently Locate and prevent the air intake if required install ventilation systems at specified locations 6 Pump pumping again...

Страница 22: ...ent and putting your personal health at risk NOTICE Disposal in domestic waste is prohibited In the European Union this symbol may be included on the product the packaging or the accompanying document...

Страница 23: ......

Страница 24: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: