background image

en

Installation and operating instructions • Wilo-Rexa FIT-S • Ed.01/2022-03

9

CAUTION

Total damage due to moisture ingress

The ingress of moisture into the connection cable
damages the cable and the pump! Never immerse
the ends of the connection cable in fluid. Seal them
tightly during storage.

Place the pump upright (vertical) on a firm bearing surface.

Secure the pump against falling over and slipping!

Store the pump for a maximum of one year. Consult the cus-
tomer service before storing the device for more than one year.

Storage conditions:

Maximum: -15 to +60 °C (5 to 140 °F), max. humidity: 90 %,
non-condensing.

Recommended: 5 to 25 °C (41 to 77 °F), relative humidity: 40
to 50 %.

Protect the pump from direct exposure to sunlight. Extreme
heat can cause damage!

Do not store the pump in rooms where welding work is carried
out. The resulting gases or radiation can corrode the elastomer
parts and coatings.

Seal the suction and discharge connection tightly.

Protect the connection cable against kinking and damage.
Maintain a constant bend radius!

4

Application/use

4.1

Intended use

For pumping in commercial areas of:

Sewage containing faeces

Wastewater (with small amounts of sand)

Sewage pumping according to (DIN) EN 12050

The pumps meet the requirements of EN 12050-1.

4.2

Improper use

DANGER

Explosion due to pumping of explosive fluids!

Pumping of highly flammable and explosive fluids
(gasoline, kerosene, etc.) in pure form is strictly pro-
hibited. There is a risk of fatal injury due to explo-
sion! The pumps are not designed for these fluids.

The submersible pumps must 

not be used

 for pumping:

Untreated sewage

Drinking water

Fluids containing hard components (such as stones, wood,
metal, etc.)

Fluids containing high quantities of abrasive contents (e.g.
sand, gravel).

Intended use also includes compliance with this manual. Any other
use is regarded as non-compliant with intended use.

5

Product description

5.1

Description

Fully submersible grinder pump for stationary and portable wet
well installation in intermittent operation.

1

2

3

4

5

6

7

Fig. 2: 

Overview

1

Handle/attachment point

2

Motor housing

3

Discharge connection

4

Macerator

5

Hydraulics housing

6

Seal housing

7

Connection cable

Rexa FIT-S ... /M ... /P

Sewage pump with radial macerator with double shear effect. Hori-
zontal discharge port with flange and oval connection. Hydraulics
housing and impeller made of grey cast iron; macerator made of
hardened cutting steel. Surface-cooled 1~ motor with self-
switching thermal motor monitoring. Oil-filled sealing chamber
with two mechanical seals. Stainless steel motor housing. Detach-
able connection cable with capacitor box and plug (CEE 7/7).

Rexa FIT-S ... /M ... /A

Sewage pump with radial macerator with double shear effect. Hori-
zontal discharge port with flange and oval connection. Hydraulics
housing and impeller made of grey cast iron; macerator made of
hardened cutting steel. Surface-cooled 1~ motor with self-
switching thermal motor monitoring. Oil-filled sealing chamber
with two mechanical seals. Stainless steel motor housing. Detach-
able connection cable with capacitor box, float switch and plug
(CEE 7/7).

Rexa FIT-S ... /T ... /O

Sewage pump with radial macerator with double shear effect. Hori-
zontal discharge port with flange and oval connection. Hydraulics
housing and impeller made of grey cast iron; macerator made of
hardened cutting steel. Surface-cooled 3~ motor with thermal
motor monitoring. Oil-filled sealing chamber with two mechanical
seals. Stainless steel motor housing. Detachable connection cable
with bare cable ends.

5.2

Materials

Pump housing: EN-GJL-250 (ASTM A48 Class 35/40B)

Impeller: EN-GJL-250 (ASTM A48 Class 35/40B)

Macerator: 1.4528/59 HRC (AISI 440B+Co)

Содержание Rexa FIT-S

Страница 1: ...Pioneering for You Wilo Rexa FIT S 6092602 Ed 01 2022 03 en Installation and operating instructions...

Страница 2: ...Rexa FIT S http qr wilo com 414 Rexa FIT https qr wilo com 771...

Страница 3: ...ials 9 5 3 Technical data 10 5 4 Type key 10 5 5 Scope of delivery 10 5 6 Accessories 10 6 Installation and electrical connection 10 6 1 Personnel qualifications 10 6 2 Installation types 10 6 3 Opera...

Страница 4: ...ent Non compliance with these instructions Improper use Incorrect storage or transport Incorrect installation or dismantling Insufficient maintenance Unauthorised repairs Inadequate construction site...

Страница 5: ...them during use of the product supervisor Persons with limited physical sensory or mental capacities Use of this product is pro hibited 2 3 Personal protective equipment The protective equipment spec...

Страница 6: ...quipment e g overvoltage undervoltage or phase failure relay etc Residual current device RCD Install a residual current device RCD in ac cordance with the regulations of the local en ergy supply compa...

Страница 7: ...et and pressure pipe Ensure minimum water submersion by using dry running protection Sound pressure level depends on several factors installation duty point etc Measure the current noise level under o...

Страница 8: ...ied to the transport company or the man ufacturer on the day of receipt of shipment Subsequently notified defects can no longer be asserted 3 2 Transport CAUTION Soaked packaging may tear The product...

Страница 9: ...contents e g sand gravel Intended use also includes compliance with this manual Any other use is regarded as non compliant with intended use 5 Product description 5 1 Description Fully submersible gri...

Страница 10: ...y for rated voltage P Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 5 5 Scope of delivery Pump Installation and operating instructions...

Страница 11: ...le length are sufficient for the selected installation type Installation of switchgear Observe information in the manufac turer s instructions IP class overflow proof potentially explos ive atmosphere...

Страница 12: ...ace If the pump is used at the same location for a longer period of time bolt the pump support foot to the floor This reduces vi brations and enables quiet operation 1 6 5 3 4 2 OFF S1 S2 S3 Fig 5 Por...

Страница 13: ...l relay motor protection switch with temperature compensation differential triggering and anti reactivation device in accordance with the local regulations In case of sensitive mains make provision fo...

Страница 14: ...protection to the rated current according to the rating plate Partial load operation Set the motor protection to 5 above the current measured at the duty point 6 5 6 2 Soft starter Full load Set the m...

Страница 15: ...nding on the fill level ON OFF Switch the pump on and off in operating mode HAND Pump with attached plug Single phase AC version 1 motor Insert the plug into the socket the pump is ready for operation...

Страница 16: ...rotect the pump from frost and ice Minimum fluid temperature 3 C 37 F 1 Switch off the pump 2 Secure the operating point against being switched on again by unauthorised persons e g lock main switch Th...

Страница 17: ...equipment to the attachment point on the pump 3 Lift the pump approximately 30 cm 10 in above the ground 4 Spray the pump with clean water from top to bottom 5 Guide the water jet inwards through the...

Страница 18: ...remain constant Slight fluctu ations depend on the characteristics of the fluid Power consump tion can provide an early indication of damage or malfunctions in the impeller bearings or motor which can...

Страница 19: ...customer service 8 Pour in operating fluid Rotate the pump until the opening points upwards Pour the operating fluid into the opening Comply with the specifications for the operating fluid type and qu...

Страница 20: ...Wet fastening screw with thread locking fluid and screw it into cutting head Tighten the fastening screw hand tight 7 Secure the cutting head Insert wedge between cutting head and cutting plate CAUTIO...

Страница 21: ...r cushion in the pipe system Vent the pipe system If air cushions occur frequently Locate and prevent the air intake if required install ventilation systems at specified locations 6 Pump pumping again...

Страница 22: ...ent and putting your personal health at risk NOTICE Disposal in domestic waste is prohibited In the European Union this symbol may be included on the product the packaging or the accompanying document...

Страница 23: ......

Страница 24: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: