Installation and operating instructions • Wilo-Rexa FIT-S • Ed.01/2022-03

21

3.

The sealing chamber control (optional) has interrupted the
electric circuit (connection-related)

See “Fault: Mechanical seal leakage, sealing chamber con-
trol reports a fault and switches the pump off”.

Fault: Pump starts up, motor protection trips after short period

1.

Motor protection switch set incorrectly.

Have the adjustment of the trigger checked and corrected
by a qualified electrician.

2.

Increased power consumption due to major voltage drop.

Have the voltage of individual phases checked by a quali-
fied electrician. Contact the electricity distribution net-
work.

3.

There are only two phases at the connection.

Have the connection checked and corrected by a qualified
electrician.

4.

Excessive differences in voltage between the phases.

Have the voltage of individual phases checked by a quali-
fied electrician. Contact the electricity distribution net-
work.

5.

Incorrect direction of rotation.

Have the connection corrected by a qualified electrician.

6.

Increased power consumption through jammed hydraulics.

Clean the hydraulics and check the inlet.

7.

The density of the fluid is too high.

Contact customer service.

Fault: Pump runs, there is no volume flow

1.

There is no fluid.

Check the inlet, open all gate valves.

2.

Inlet clogged.

Check the inlet and remove clogging.

3.

Hydraulics jammed.

Clean the hydraulics.

4.

Pipe system on the pressure side or pressure hose clogged.

Remove clogging and replace the damaged components if
necessary.

5.

Intermittent operation.

Check the switching system.

Fault: Pump starts, duty point is not reached

1.

Inlet clogged.

Check the inlet and remove clogging.

2.

Slide valves on the pressure side closed.

Completely open all gate valves.

3.

Hydraulics jammed.

Clean the hydraulics.

4.

Incorrect direction of rotation.

Have the connection corrected by a qualified electrician.

5.

Air cushion in the pipe system.

Vent the pipe system.

If air cushions occur frequently: Locate and prevent the air
intake, if required install ventilation systems at specified
locations.

6.

Pump pumping against excessive pressure.

Open all gate valves on the pressure side completely.

7.

Signs of wear on the hydraulics.

Have the components (impeller, suction port, pump hous-
ing) checked and replaced by customer service.

8.

Pipe system on the pressure side or pressure hose clogged.

Remove clogging and replace the damaged components if
necessary.

9.

Strongly gassing fluid.

Contact customer service.

10. The connection only has two phases.

Have the connection checked and corrected by a qualified
electrician.

11. Excessive decrease in the fill level during operation.

Check supply/capacity of the system.

Have the switching points of the level control checked and
adjusted if necessary.

Fault: The pump does not run smoothly and is noisy

1.

Improper duty point.

Check the pump configuration and the duty point, contact
customer service.

2.

Hydraulics jammed.

Clean the hydraulics.

3.

Strongly gassing fluid.

Contact customer service.

4.

There are only two phases at the connection.

Have the connection checked and corrected by a qualified
electrician.

5.

Incorrect direction of rotation.

Have the connection corrected by a qualified electrician.

6.

Signs of wear on the hydraulics.

Have the components (impeller, suction port, pump hous-
ing) checked and replaced by customer service.

7.

Motor bearings have worn.

Inform customer service; send the pump back to the fact-
ory for overhauling.

8.

Pump is installed under tension.

Check installation, install rubber compensators if neces-
sary.

Fault: Sealing chamber control reports fault or switches the
pump off

1.

Condensation water build-up due to extended storage or high
temperature fluctuations.

Operate the pump for a short period (max. 5 min.) without
pencil electrode.

2.

Increased leakage when running in new mechanical seals.

Change the oil.

3.

Pencil electrode cable is defective.

Replace the pencil electrode.

4.

Mechanical seal is defective.

Inform customer service.

Содержание Rexa FIT-S

Страница 1: ...Pioneering for You Wilo Rexa FIT S 6092602 Ed 01 2022 03 en Installation and operating instructions...

Страница 2: ...Rexa FIT S http qr wilo com 414 Rexa FIT https qr wilo com 771...

Страница 3: ...ials 9 5 3 Technical data 10 5 4 Type key 10 5 5 Scope of delivery 10 5 6 Accessories 10 6 Installation and electrical connection 10 6 1 Personnel qualifications 10 6 2 Installation types 10 6 3 Opera...

Страница 4: ...ent Non compliance with these instructions Improper use Incorrect storage or transport Incorrect installation or dismantling Insufficient maintenance Unauthorised repairs Inadequate construction site...

Страница 5: ...them during use of the product supervisor Persons with limited physical sensory or mental capacities Use of this product is pro hibited 2 3 Personal protective equipment The protective equipment spec...

Страница 6: ...quipment e g overvoltage undervoltage or phase failure relay etc Residual current device RCD Install a residual current device RCD in ac cordance with the regulations of the local en ergy supply compa...

Страница 7: ...et and pressure pipe Ensure minimum water submersion by using dry running protection Sound pressure level depends on several factors installation duty point etc Measure the current noise level under o...

Страница 8: ...ied to the transport company or the man ufacturer on the day of receipt of shipment Subsequently notified defects can no longer be asserted 3 2 Transport CAUTION Soaked packaging may tear The product...

Страница 9: ...contents e g sand gravel Intended use also includes compliance with this manual Any other use is regarded as non compliant with intended use 5 Product description 5 1 Description Fully submersible gri...

Страница 10: ...y for rated voltage P Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 5 5 Scope of delivery Pump Installation and operating instructions...

Страница 11: ...le length are sufficient for the selected installation type Installation of switchgear Observe information in the manufac turer s instructions IP class overflow proof potentially explos ive atmosphere...

Страница 12: ...ace If the pump is used at the same location for a longer period of time bolt the pump support foot to the floor This reduces vi brations and enables quiet operation 1 6 5 3 4 2 OFF S1 S2 S3 Fig 5 Por...

Страница 13: ...l relay motor protection switch with temperature compensation differential triggering and anti reactivation device in accordance with the local regulations In case of sensitive mains make provision fo...

Страница 14: ...protection to the rated current according to the rating plate Partial load operation Set the motor protection to 5 above the current measured at the duty point 6 5 6 2 Soft starter Full load Set the m...

Страница 15: ...nding on the fill level ON OFF Switch the pump on and off in operating mode HAND Pump with attached plug Single phase AC version 1 motor Insert the plug into the socket the pump is ready for operation...

Страница 16: ...rotect the pump from frost and ice Minimum fluid temperature 3 C 37 F 1 Switch off the pump 2 Secure the operating point against being switched on again by unauthorised persons e g lock main switch Th...

Страница 17: ...equipment to the attachment point on the pump 3 Lift the pump approximately 30 cm 10 in above the ground 4 Spray the pump with clean water from top to bottom 5 Guide the water jet inwards through the...

Страница 18: ...remain constant Slight fluctu ations depend on the characteristics of the fluid Power consump tion can provide an early indication of damage or malfunctions in the impeller bearings or motor which can...

Страница 19: ...customer service 8 Pour in operating fluid Rotate the pump until the opening points upwards Pour the operating fluid into the opening Comply with the specifications for the operating fluid type and qu...

Страница 20: ...Wet fastening screw with thread locking fluid and screw it into cutting head Tighten the fastening screw hand tight 7 Secure the cutting head Insert wedge between cutting head and cutting plate CAUTIO...

Страница 21: ...r cushion in the pipe system Vent the pipe system If air cushions occur frequently Locate and prevent the air intake if required install ventilation systems at specified locations 6 Pump pumping again...

Страница 22: ...ent and putting your personal health at risk NOTICE Disposal in domestic waste is prohibited In the European Union this symbol may be included on the product the packaging or the accompanying document...

Страница 23: ......

Страница 24: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: