Installation and operating instructions • Wilo-Rexa FIT-S • Ed.01/2022-03

Motor housing: 1.4301 (AISI 304)

Shaft: 1.4401 (AISI 316)

Seal on the motor side: C/MgSiO

4

Seal on the fluid side: SiC/SiC

Seal, static: NBR (nitrile)

5.3

Technical data

General

Date of manufacture* [MFY]

See rating plate

Mains connection [U/f]

See rating plate

Power consumption [P

1

]

See rating plate

Rated power [P

2

]

See rating plate

Max. delivery head [H]

See rating plate

Max. volume flow [Q]

See rating plate

Activation type [AT]

Direct

Fluid temperature [t]

3 … 40 °C (37 … 104 °F)

Fluid temperature, short-term

60 °C (140 °F) for 3 min

Protection class

IP68

Insulation class [Cl.]

F

Speed [n]

See rating plate

Max. switching frequency

60/h

Cable length

10 m (33 ft)

Permissible immersion depth
with attached connection cable
[

8

]

7 m (23 ft)

Immersion depth, max.

20 m (66 ft)

Operating modes

Immersed

S1

Non-immersed

S2-15 min; S3 10%

Discharge connection

Flange connection

DN 32/40, PN 10; ANSI B16.1,
Size 1.5, Class 125

Oval connection

36 mm

Extended use

Explosion protection

-

Operation on frequency con-
verter

-

*The date of manufacture is stated in accordance with ISO 8601:
JJJJWww

JJJJ = year

W = abbreviation for week

ww = calendar week

5.4

Type key

Ex-
ample:

Rexa FIT-S03-123A/21M015-523/P

Rexa

Submersible sewage pump

FIT

Series

S

Macerator

03

Nominal diameter of the discharge connection:
DN 32/40

123

Hydraulics type

A

Material version: Standard

2

Number of poles

1

IE class

M

Mains connection version:

M = single-phase current (1~)

T = three-phase current (3~)

15

Value/10 = rated power P

2

 in kW

-

Not Ex-rated

5

Mains frequency: 5 = 50 Hz/6 = 60 Hz

23

Key for rated voltage

P

Additional electrical equipment:

O = with bare cable end

P = with plug (CEE 7/7)

A = with float switch and plug (CEE 7/7)

5.5

Scope of delivery

Pump

Installation and operating instructions

5.6

Accessories

Connection cable with fixed cable lengths:

1~ motor: up to max. 30 m (98 ft).

3~ motor: up to max. 50 m (164 ft).

External pencil electrode for monitoring the sealing chamber

Suspension unit for wet well installation

Pump support foot for portable installation

Level control devices

Fixation sets with anchor bolts

Fixation accessories and chains

Switchgear, relays and plugs

6

Installation and electrical connection

6.1

Personnel qualifications

Electrical work: qualified electrician
Person with appropriate technical training, knowledge and ex-
perience who can identify and prevent electrical hazards.

Installation/dismantling work: trained sewage technology pro-
fessional
Fixation and pipework in wet well and dry well installation, lift-
ing equipment, basic knowledge of wastewater facilities

6.2

Installation types

Vertical stationary wet well installation with suspension unit

Vertical portable wet well installation with pump support foot

6.3

Operator responsibilities

Observe locally applicable accident prevention and safety regu-
lations.

Observe all regulations for working with heavy loads and under
suspended loads.

Provide protective equipment. Ensure that the protective
equipment is worn by personnel.

Observe local sewage technology regulations for the operation
of sewage systems.

Avoid pressure surges!
Pressure surges can occur in long pressure pipes with steep ter-
rain. These pressure surges can lead to the destruction of the
pump!

Ensure the cooling time of the motor depending on the operat-
ing conditions and the size of the pump chamber.

Содержание Rexa FIT-S

Страница 1: ...Pioneering for You Wilo Rexa FIT S 6092602 Ed 01 2022 03 en Installation and operating instructions...

Страница 2: ...Rexa FIT S http qr wilo com 414 Rexa FIT https qr wilo com 771...

Страница 3: ...ials 9 5 3 Technical data 10 5 4 Type key 10 5 5 Scope of delivery 10 5 6 Accessories 10 6 Installation and electrical connection 10 6 1 Personnel qualifications 10 6 2 Installation types 10 6 3 Opera...

Страница 4: ...ent Non compliance with these instructions Improper use Incorrect storage or transport Incorrect installation or dismantling Insufficient maintenance Unauthorised repairs Inadequate construction site...

Страница 5: ...them during use of the product supervisor Persons with limited physical sensory or mental capacities Use of this product is pro hibited 2 3 Personal protective equipment The protective equipment spec...

Страница 6: ...quipment e g overvoltage undervoltage or phase failure relay etc Residual current device RCD Install a residual current device RCD in ac cordance with the regulations of the local en ergy supply compa...

Страница 7: ...et and pressure pipe Ensure minimum water submersion by using dry running protection Sound pressure level depends on several factors installation duty point etc Measure the current noise level under o...

Страница 8: ...ied to the transport company or the man ufacturer on the day of receipt of shipment Subsequently notified defects can no longer be asserted 3 2 Transport CAUTION Soaked packaging may tear The product...

Страница 9: ...contents e g sand gravel Intended use also includes compliance with this manual Any other use is regarded as non compliant with intended use 5 Product description 5 1 Description Fully submersible gri...

Страница 10: ...y for rated voltage P Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 5 5 Scope of delivery Pump Installation and operating instructions...

Страница 11: ...le length are sufficient for the selected installation type Installation of switchgear Observe information in the manufac turer s instructions IP class overflow proof potentially explos ive atmosphere...

Страница 12: ...ace If the pump is used at the same location for a longer period of time bolt the pump support foot to the floor This reduces vi brations and enables quiet operation 1 6 5 3 4 2 OFF S1 S2 S3 Fig 5 Por...

Страница 13: ...l relay motor protection switch with temperature compensation differential triggering and anti reactivation device in accordance with the local regulations In case of sensitive mains make provision fo...

Страница 14: ...protection to the rated current according to the rating plate Partial load operation Set the motor protection to 5 above the current measured at the duty point 6 5 6 2 Soft starter Full load Set the m...

Страница 15: ...nding on the fill level ON OFF Switch the pump on and off in operating mode HAND Pump with attached plug Single phase AC version 1 motor Insert the plug into the socket the pump is ready for operation...

Страница 16: ...rotect the pump from frost and ice Minimum fluid temperature 3 C 37 F 1 Switch off the pump 2 Secure the operating point against being switched on again by unauthorised persons e g lock main switch Th...

Страница 17: ...equipment to the attachment point on the pump 3 Lift the pump approximately 30 cm 10 in above the ground 4 Spray the pump with clean water from top to bottom 5 Guide the water jet inwards through the...

Страница 18: ...remain constant Slight fluctu ations depend on the characteristics of the fluid Power consump tion can provide an early indication of damage or malfunctions in the impeller bearings or motor which can...

Страница 19: ...customer service 8 Pour in operating fluid Rotate the pump until the opening points upwards Pour the operating fluid into the opening Comply with the specifications for the operating fluid type and qu...

Страница 20: ...Wet fastening screw with thread locking fluid and screw it into cutting head Tighten the fastening screw hand tight 7 Secure the cutting head Insert wedge between cutting head and cutting plate CAUTIO...

Страница 21: ...r cushion in the pipe system Vent the pipe system If air cushions occur frequently Locate and prevent the air intake if required install ventilation systems at specified locations 6 Pump pumping again...

Страница 22: ...ent and putting your personal health at risk NOTICE Disposal in domestic waste is prohibited In the European Union this symbol may be included on the product the packaging or the accompanying document...

Страница 23: ......

Страница 24: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: