Commissioning / Functional test
36
WILO SE 2020-07
2. Position the wires of the digital temperature sensor according to their colours
(WH - white, RD - red, BK - black).
8
Commissioning / Functional test
NOTICE
It is recommended to test together with the connected system.
The pump's installation and operating instructions are needed for some settings.
8.1
Settings
Stratos Smart IF module
Read the installation and operating instructions for the Stratos series to
configure settings in Stratos pumps.
Smart IF module
In order to configure settings in the < 5.x.x.x > menus, DIP switch 1 (no
key symbol) under the terminal box cover must be set to "ON".
Table 6:
Settings
8.2
Wilo Net ID
Stratos Smart IF module
Adjust Wilo Net ID in pump menu
.
OFF deactivates the interface.
Smart IF module
Adjust Wilo Net ID in pump menu < 5.2.3.0 >.
OFF deactivates the interface.
Table 7:
Wilo Net ID
8.3
Parameter A - Bluetooth block
Stratos Smart IF module
0 enables pairing with the device, 1 blocks pairing.
Set to 1 to not permit any new devices.
Smart IF module
0 enables pairing with the device, 1 blocks pairing.
Set to 1 to not permit any new devices.
Parameter A is adjusted in menu < 5.2.4.0 >.
Table 8:
Parameter A - Bluetooth block
8.4
Parameter C - delete Bluetooth connection key
Enter 1 as the parameter to delete all Bluetooth connection keys (pairings). After the
command has been run, the value automatically returns to 0.
Delete the connection key to delete the pairing of all previously paired devices. This
prevents previously paired devices from gaining unauthorised access at a later point.
The group of authorised remote controls can be checked along with block A.