background image

 
 

PMP-098 

Oil Furnaces

 – 

Furnace Manual

 

24

 

 

11/13

 

Components and replacement parts (continued) 

Table 14: Parts list with 4-speed motor (PSC) 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03409

HEAT EXCHANGER

Heat exchanger only

2

J06L002

SEAL STRIP, 1/4 x 1/8 x 25'

3

B03429

WIRE CHANNEL, INT.

4

B03420-02

FRONT PANEL ASSEMBLY

Panel, insulation and labels included

5

B03444

FRONT PANEL INSULATION

6

B03450-01

BAFFLE, LATERAL

7

B03426-03

SIDE PANEL ASSEMBLY (RIGHT)

Panel, insulation and baffle included

8

B03473

SIDE PANEL INSULATION

9

L04J001

CABLE CLAMP, 9/16" WHITE

10

F06F015

WASHER, ZINC 1 7/16"

11

Z99F061

OBSERVATION PORT

12

L04I013

STRAIN RELIEF BUSHING

13

B03445-01

WIRE CHANNEL (SWITCH)

14

L07F003

ROCKER SWITCH, SPST

15

R02R006

HIGH LIMIT 36T01B7 150-20F, 7"

16

B03454

ELECTRICAL KIT, BURNER

17

B03453

ELECTRICAL KIT, TT

18

B03630-01

BAFFLE

One baffle included

19

B03428

SMOKE OUTLET GASKET

20

B03416-01

RADIATOR BAFFLE

Item # 19 included

21

F07O001

FLANGE NUT, HEXAGONAL 3/8-16NC BRASS

22

F07F011

HEX NUT 3/8-16NC ZINC  

23

Z99F050

HANDLE , RECESSED BLACK

24

B03419-11

BLOWER DOOR ASSEMBLY

Door and labels included

25

B03439

COVER, ELECTRICAL BOX

26

B03535-01

REPLACEMENT BLOWER ASSEMBLY

Blower, motor and capacitor included

27

B03470

FLOOR

28

B03298-01

FILTER RACK FRAME

29

B03426-04

SIDE PANEL ASSEMBLY (LEFT)

Panel, insulation and baffle included

30

B03299-01

FILTER RACK ACCESS

31

B03450-02

LATERAL BAFFLE

32

B30513

BLOWER SLIDE

One slide included

33

B03441

BLOWER DIVIDER

34

B03451

REAR BAFFLE

35

B03427-01

REAR PANEL ASSEMBLY

Panel, insulation and baffles included

36

B03471

REAR PANEL INSULATION

37

B03457-01

ELECTRICAL KIT, BLOWER

38

L01I001

CAPACITOR 5MF

39

B01024

CAPACITOR HOLDER

40

B03456

ELECTRICAL KIT, BOARD

41

R99G004

ELECTRONIC BOARD, UTEC 1158-110

42

B03440

ELECTRICAL BOX

43

L01F009

TRANSFORMER, 120-24Volt, 40VA

44

B03438

SUPPORT, ELECTRONICS BOX

45

R02R007

HIGH LIMIT, 120-20F,  1.75''

46

B03437

BLOWER SLIDE

One slide included

47

B03720-02

BLOWER, 100-8R DD 0,50 PP

Housing, wheel and label only

48

B01888

MOTOR SUPPORT ASSEMBLY

Legs, band and hardware included

49

B01890-01

MOTOR ASSEMBLY, 1/3 HP

Complete with legs

50

L01G009

CONTROL CARD FUSE - 3 AMPS

DOWNFLOW BASE

B03464-01

HORIZONTAL FLOW BASE

B00488-01

VENT TERMINAL KIT 4''

For sealed combustion

4" INSULATED FLEX VENT 10ft

For sealed combustion

4" INSULATED FLEX VENT 15ft

For sealed combustion

4" INSULATED FLEX VENT 20ft

For sealed combustion

PROTECTION PLATE BURNER NX

For down flow installation only

AMP098 (W-T) 4-SPEED MOTOR (PSC)

ACCESSORIES

DFB-102
HFB-101
VTK-54
IFV-410

B03789

IFV-415
IFV-420

 

B50122A

Содержание PMP-098

Страница 1: ...antial property damage When calling or writing about the furnace Please indicate furnace model number and serial number from rating label You may list the serial number and model number in the space p...

Страница 2: ...ows 20 Always connect and seal a return air duct to the furnace unless the furnace is located in a large space such as an unpartitioned basement Route the return air duct to an adjacent room if no ret...

Страница 3: ...e minimum clearances from combustible material for each of the positions are specified in Table 1 If the furnace is installed in a basement or on a dirt floor in a crawl space for example it is recomm...

Страница 4: ...ase HFB 101 can be used to ensure these clearances Refer to the instructions supplied with the base The burner must always be installed in the same manner regardless of the discharge position of the f...

Страница 5: ...ore starting the burner for the first time adjust the air and turbulator settings to those listed in this manual Table 11 Once the burner becomes operational final adjustments will be required Refer t...

Страница 6: ...led by a qualified service technician A positive pressure venting system Sealed Combustion System or Direct Vent must NOT use the BVSO Follow the instructions supplied with the venting system This dev...

Страница 7: ...om the outside Follow the instructions provided with the burner the fresh air supply kit or the side wall venting kit 1 9 OIL TANK Fire and explosion hazard Use only approved heating type oil in this...

Страница 8: ...k satisfactorily on either heating or cooling 1 10 1 2 Determine duct dimensions Table 3 page 9 and Table 4 page 10 provide typical round and rectangular duct sizes for rectangular and flat oval galva...

Страница 9: ...7 7 6 6 900 14 58 41 31 25 21 19 17 14 12 11 10 9 8 8 7 7 7 1000 16 64 45 34 28 23 20 18 15 13 11 10 9 9 8 8 7 7 1100 16 72 49 38 30 25 22 19 16 14 12 11 10 9 9 8 8 7 1200 16 54 41 33 27 24 21 17 15 1...

Страница 10: ...2 600 12 59 38 28 22 19 16 15 13 700 12 69 44 32 25 21 18 16 15 13 800 14 50 36 29 24 20 18 16 14 900 14 56 41 32 26 22 20 18 15 1000 16 63 45 35 29 24 22 19 17 15 1100 16 69 49 38 31 26 23 21 18 16 1...

Страница 11: ...same the RED wire must be moved to UNUSED LEADS on the electronic board and the jumper provided with the BLUE wire must be used between the HEAT and COOL terminals The blower start stop delays can be...

Страница 12: ...lace and the blower rail locking screws are well tightened 3 The Blocked Vent Shut Off BVSO is installed according to instructions for chimney venting 4 The oil supply valve is open 5 The burner Reset...

Страница 13: ...himney installation and 0 03 to 0 15 W C for direct vent installation A high pressure condition may be caused by excessive combustion air due to the air band being too wide open or a lack of flue draf...

Страница 14: ...e unit the heat exchanger and combustion chamber should be inspected to determine if replacement is required 8 After the cleaning replace the heat exchanger baffles flue collar plate and oil burner 9...

Страница 15: ...ecked not to exceed 85 F and the blower speed adjusted if necessary 19 Was the thermostat heat anticipator set per wiring diagram Furnace operation continued 20 Was the burner started and tested per b...

Страница 16: ..._____________________________ Date installed ________________________ Installation instructions have been followed Checkout sequence has been performed Above information is certified to be correct Inf...

Страница 17: ...d amps Minimum ampacity for wiring sizing Maximum fuse size amps Ship weight pounds PMP 098 DD 55 85 1 X 20 x 20 115 60 1 12 2 13 7 15 125 PMP 098 VS 55 85 1 X 20 x 20 115 60 1 10 3 12 2 15 125 0 25 W...

Страница 18: ...van Pump pressure PSIG Head Low firing rate baffle Burner tube insertion length Inch ATC Head Air setting 70 000 0 50 86 1 0 40 60W 155 Yes 32229 2 0 84 000 0 60 85 4 0 50 60W 145 Yes 32229 2 5 98 000...

Страница 19: ...air adjustment Head Air 70 000 0 50 86 2 0 50 60H 100 0 50 13 84 000 0 60 85 4 0 50 60H 150 0 50 23 98 000 0 70 83 8 0 55 60H 165 60 65 30 70 000 0 50 86 2 0 50 60H 100 0 50 13 84 000 0 60 85 4 0 50...

Страница 20: ...me Off Delay CFM Level Time A 1 OFF 2 OFF 0 75 13 45 sec 19 30 sec 38 3 min B 1 ON 2 OFF 0 65 13 45 sec 19 60 sec 38 3 min C 1 OFF 2 ON 0 50 13 60 sec 13 60 sec 38 3 min D 1 ON 2 ON All 13 30 sec 100...

Страница 21: ...PMP 098 Oil Furnaces Furnace Manual 11 13 21 5 DIMENSIONS AND RATINGS continued Figure 12 Wiring diagram 4 speed motor PSC...

Страница 22: ...PMP 098 Oil Furnaces Furnace Manual 22 11 13 5 DIMENSIONS AND RATINGS continued Figure 13 Wiring diagram variable speed motor ECM...

Страница 23: ...PMP 098 Oil Furnaces Furnace Manual 11 13 23 6 Components and replacement parts Figure 14 Parts list with 4 speed motor PSC B50122A...

Страница 24: ...or and capacitor included 27 B03470 FLOOR 28 B03298 01 FILTER RACK FRAME 29 B03426 04 SIDE PANEL ASSEMBLY LEFT Panel insulation and baffle included 30 B03299 01 FILTER RACK ACCESS 31 B03450 02 LATERAL...

Страница 25: ...PMP 098 Oil Furnaces Furnace Manual 11 13 25 6 Components and replacement parts continued Figure 15 Parts list with variable speed motor ECM B50123A...

Страница 26: ...wer motor and capacitor included 26 B03470 FLOOR 27 B03298 01 FILTER RACK FRAME 28 B03426 02 SIDE PANEL ASSEMBLY LEFT Panel insulation and baffle included 29 B03299 01 FILTER RACK ACCESS 30 B03450 02...

Страница 27: ...f the furnace oil burner should shut down on flame failure the burner primary control will lock out Ask your service technician to show you the correct procedure to reset the primary control button NE...

Страница 28: ...PMP 098 Oil Furnaces Furnace Manual X40204 Rev B 11 13...

Отзывы: