PMP-098
Oil Furnaces
–
Furnace Manual
11/13
19
5.
DIMENSIONS AND RATINGS (continued)
Table 11: Model PMP-098 Burner data (suite)
Model
Input
BTU/h
(*)
Firing rate
USGPH
(*)
AFUE
(***)
Nozzle
(Delavan)
(**)
Pump
pressure
(PSIG)
(*)
Burner tube
insertion
length (Inch)
Combustion air
adjustment
(Turbulator
/Damper)
70,000
0.50
86.4%
0.40 - 70A
155
0 / 1,5
84,000
0.60
85.9%
0.50 - 70A
145
0 / 2,5
98,000
0.70
84.5%
0.60 - 70A
135
1 / 3,5
70,000
0.50
86.4% ‡
0.40 - 70A
155
0 / 1,5
84,000
0.60
85.9% ‡
0.50 - 70A
145
0 / 2,5
Model
Input
BTU/h
(*)
Firing rate
USGPH
(*)
AFUE
(***)
Nozzle
(Danfoss)
(**)
Pump
pressure
(PSIG)
(*)
Burner tube
insertion
length (Inch)
Combustion air
adjustment
(Head/Air)
70,000
0.50
86.2%
0.50 - 60H
100
0,50 - 13%
84,000
0.60
85.4%
0.50 - 60H
150
0,50 - 23%
98,000
0.70
83.8%
0.55 - 60H
165
,60/,65 - 30%
70,000
0.50
86.2% ‡
0.50 - 60H
100
0,50 - 13%
84,000
0.60
85.4% ‡
0.50 - 60H
150
0,50 - 23%
1 3/4"
CARLIN BURNER; MODEL EZ-LF (Chimney)
PMP-098-DD
PMP-098-VS
RIELLO BURNER; MODEL 40-F3 (Chimney)
2 3/4"
PMP-098-DD
PMP-098-VS
C US
PMP furnaces are CSA design
certified for installation
on combustible flooring.
‡=
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature are under 400°F.
- Adjust the total flue gas temperature between 400°F and 575°F (330°F and 505°F net approximately)
** Default Installed Nozzle in bold characters
*** AFUE values established after minimum 20 hours of operation.