background image

7

SHELF/SLIDE FITTING  

When positioning slides on standard cabinets and 

counters, present slide to racking by holding it in 

the opposite hand to the side of the cabinet to that 

which they are to be applied. Present slide at 45° 

angle (figure 1). When in place, let slide drop into 

position to create a horizontal ledge on which the 

shelves will sit. 

The WMP135 models are fitted with pilaster and 

clips (figure 2) for fitting. 

 

LOADING / SHELF DISTRIBUTION 

Before loading, allow the appliance to reach its 

normal operating temperature.

• 

Never load beyond capacity.

• 

Always store items within shelves.

• 

Uniform product temperature is maintained by 

air circulation, ensure even loading.

• 

Do not place items against the rear plenum or 

pushed against side walls.

When loading the appliance, please ensure that its 

load is equally distributed throughout and ensure air 

can circulate around and through stored products. 
Care should be taken when loading the appliance. 

Do not obstruct the air ducts. Take care of any parts 

with possible sharp edges.

 

 

LOCKING FACILITY 

On models with a locking facility, it is recommended 

that the key be removed from its lock during normal 

working use. This will prevent bending or breaking 

of the key which could result in the lock having to be 

replaced.
Removing the key will also prevent accidental 

locking when the door is open. This will prevent the 

door from closing properly and cause the interior 

temperature to rise. If not checked in time, a loss of 

product may result.

FIG 1.

FIG 2.

INSTALLATION

Содержание Medi+ LWMP620

Страница 1: ...nd will use the necessary safety equipment and take the necessary precautions required of their intended work Improper installation maintenance or repair may put the user at considerable risk Williams...

Страница 2: ...led by persons who are appropriately trained skilled and competent to properly and safely carry out the work and serviced by qualified engineers for the handling of hydrocarbon refrigerants Ensure pro...

Страница 3: ...the replacement of parts is required the equipment must be safely disconnected and isolated from the power supply using a lock off system at the isolation device It is advised that the electrical sup...

Страница 4: ...iosafety Manual source World Health Organisation Laboratory Biosafety Manual the current edition IMPORTANT SAFETYINFORMATION INFORMATION ON PRODUCT LIABILITY In the following cases the designated prot...

Страница 5: ...ay to reveal the polished stainless steel surface Care should be taken to ensure that no adhesive residue remains on the surface Any stubborn or tough adhesive marks can be removed by following the ad...

Страница 6: ...party supervisory networks and systems such as Building Management Systems BMS and IoT cloud based systems via an RS485 Modbus data connection This will allow for a comprehensive supervision of the eq...

Страница 7: ...e even loading Do not place items against the rear plenum or pushed against side walls When loading the appliance please ensure that its load is equally distributed throughout and ensure air can circu...

Страница 8: ...essing the i button While keeping the i button pressed press the x button to reset the value To exit the information menu either wait 10 seconds or press the x button Alarms An alarm is reported via t...

Страница 9: ...tinue in normal sequence Instead the compressor will switch to a five minute cycle which it cycles on for five minutes then off for five minutes The normal compressor cycle will be restored upon the r...

Страница 10: ...ugher spots creamy polishes like CIF original cream can be effective Light pressure should be used when cleaning with the grain The cleaning process should be repeated in order to prevent any dirt bec...

Страница 11: ...hould be checked and cleaned regularly and replaced if damaged To clean the gasket wipe with warm soapy water and a soft cloth ensuring it is completely dry before closing the door DO NOT use a sharp...

Страница 12: ...ing Shut door Remove cover and clean condenser fins with a clean brush TROUBLE SHOOTING INFORMATION FOR THE MAINS POWER SUPPLY FAILURE ALARM OPTIONAL Fault Possible Cause Action The sounder is not wor...

Страница 13: ...same quality and standard as we use to build your appliance and have been rigorously checked tested and inspected to ensure the very best quality and exact fit You can contact us directly for everythi...

Страница 14: ...number and date of installation The serial number is located on the product identification plate inside the cabinet modular product door frame or similar location It is recommended that operators shou...

Страница 15: ...ent that may affect performance 14 The customer permits persons other than those authorised by Williams Refrigeration to perform or affect repairs or adjustments to the equipment 15 If authorised repr...

Страница 16: ...k Williams Refrigeration Hong Kong Unit C 12 F Roxy Industrial Centre 58 66 Tai Lin Pai Road Kwai Chung New Territories Hong Kong Tel 852 2407 5422 Fax 852 2407 3767 sales williams hongkong com www wi...

Отзывы: