I
NSTRUCTIONS FOR
N
IGHT
S
CAN
L
ITE
&
I
NFLEXION
HD
2-22
Original Instructions
TP-5554501-B
May
2019
Figure 2-16 Vehicle Interlock Circuit Wiring Diagram
2.6.2.4 Wire Optional Auxiliary Devices to Power Relay Board
Depending on the configuration of your system, there may be additional auxiliary devices
installed such as a strobe or beacon light, or a camera. The Power Relay Board allows for up to
two auxiliary devices to be installed with a maximum amp draw of 10 amps per device.
Depending on the configuration, the customer may need to supply a cable grip and knock out an
additional access port on the control box. The cable grip size is labeled on the control box
knockout port. The cable grip must have a sealing feature against the control box wall.
For Inflexion HD, either the AUX1, AUX2, Left Light or Right Light circuit can be used to control
the payload. It is recommended to use the AUX circuits if the current is less than or equal to 10
amps. It is recommended to use the light circuits if the payload current draw is greater than 10
amps and less than or equal to 20 amps.
If no auxiliary devices shipped installed and the customer is not adding any, skip to Section
2.6.2.6.
If an auxiliary device was installed at Will-Burt, it will have been wired to the Power Relay Board
at TB6 at either AUX 1 or AUX 2 and the customer will only need to provide power for the
device (Section 2.6.2.5).
If the customer is installing an auxiliary device, the device can be wired to the Power Relay
Board as follows:
Содержание INFLEXION HD
Страница 2: ......
Страница 15: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD TP 5554501 B Original Instructions 1 3 May 2019...
Страница 32: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD 1 20 Original Instructions TP 5554501 B May 2019...
Страница 62: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD 2 30 Original Instructions TP 5554501 B May 2019...
Страница 82: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD 6 4 Original Instructions TP 5554501 B May 2019...