I
NSTRUCTIONS FOR
N
IGHT
S
CAN
L
ITE
&
I
NFLEXION
HD
TP-5554501-B
Original Instructions
2-23
May 2019
1. Run a 14 AWG (2.5 mm
2
) wire from the auxiliary device to the Control Box Assembly.
2. Locate terminal block TB6 on the Power Relay Board (P/N: 5553301).
3. Secure the wire to TB6 at either AUX 1 or AUX 2 as shown in Figure 2-17.
Figure 2-17 Power Relay Board Terminal Block TB6
2.6.2.5 Wire Power for Optional Auxiliary Devices to Power Relay Board
If an auxiliary device is installed on the system, customer fused or breaker protected power will
need to be provided to the device. The Power Relay Board allows for up to two auxiliary devices
to be installed with a maximum amp draw of 10 amps per device.
Wire customer power for the auxiliary device as follows:
1. Run a 14 AWG (2.5 mm
2
) wire from customer power to the Control Box Assembly. 15
meters (50 ft.) is the maximum permitted cable length.
2. Locate terminal block TB5 on the Power Relay Board (P/N: 5553301).
3. Secure the wire to TB5 as shown in Figure 2-18. If the auxiliary device is installed at
AUX 1 on TB6, the power should be provided at AUX 2 on TB5. If the auxiliary device is
installed at AUX 2 on TB6, the power should be provided at AUX 2 on TB5.
Figure 2-18 Power Relay Board Terminal Block TB5
Содержание INFLEXION HD
Страница 2: ......
Страница 15: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD TP 5554501 B Original Instructions 1 3 May 2019...
Страница 32: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD 1 20 Original Instructions TP 5554501 B May 2019...
Страница 62: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD 2 30 Original Instructions TP 5554501 B May 2019...
Страница 82: ...INSTRUCTIONS FOR NIGHT SCAN LITE INFLEXION HD 6 4 Original Instructions TP 5554501 B May 2019...