S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
TP-5418901-F
Original Instructions
1-17
August 2020
Mast Sensor Cable (P/N: 5433201 for 3M Cable)
The Mast Sensor Cable (Figure 1-9):
•
Transfers signals to the mast
•
Is ten feet (three meters) long as standard (other lengths available)
•
Connectors and cables are environmentally sealed to prevent dust, sand, or moisture
intrusion
•
Has 24-pin military screw-type connectors on each end for ease of installation and to
prevent environmental intrusion
•
Is unshielded and not rated for Military Specification EMI/EMC compliance. For Military
Specification EMI/EMC shielded cables should be specified at the time of the order.
Figure 1-9 Sensor Cable
Fully Extended Limit Switch Cable (P/N: 5427901)
The Fully Extended Limit Switch Cable (Figure 1-10) transfers signals between the Fully
Extended Limit Switch and the Mast Drive Housing (J7).
Figure 1-10 Fully Extended Limit Switch Cable
To Universal Control Box (J2)
(Mates with MS3102E24-28S)
MS3106E24-28P
(Clamp Style Backshell)
To Mast Drive Housing (J6)
(Mates with MS3102E24-28P)
MS3106E24-28S
(Clamp Style Backshell)