S
TILETTO
AL
O
PERATING
I
NSTRUCTIONS
8-12
Original Instructions
TP-5418901-F
August 2020
Table 7-3 Warning Codes Continued
Warning
Code
Trigger
Condition
System Response
Latch Until
Possible Cause
0040
(Legacy)
Extend/Retract
movement (50
mm) not
detected after
2 seconds of
continuous
extend/retract
command
String
Potentiometer
Failure Warning
(WRN 0040):
Allow all normal
mast functions.
NOTICE:
Mast height readout
will be inaccurate.
•
Valid signal
detected
- or -
•
5 OVERRIDE
Switch
activations
within 3
seconds
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
If seen in current
control boxes, it
likely means the DIP
switches in the
circuit board are set
incorrectly.
- Legacy -
•
Potentiometer
requires adjustment
or recalibration
•
Potentiometer failed
and requires
replacement
•
Potentiometer wiring
damaged and
requires repairs or
replacement
0080
(Legacy)
Extend/Retract
movement (50
mm) not
detected after
2 seconds of
continuous
extend/retract
command
Encoder Failure
Warning
(WRN 0080):
Allow all normal
mast functions.
NOTICE:
Mast height readout
will be inaccurate.
•
Valid signal
detected
- or -
•
5 OVERRIDE
Switch
activations
within 3
seconds
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
If seen in current
control boxes, it
likes means the DIP
switches in the
circuit board are set
incorrectly.
- Legacy -
•
Encoder requires
adjustment or
recalibration
•
Encoder failed and
requires
replacement
•
Encoder wiring
damaged and
requires repairs or
replacement
Содержание 711990491