8.2.2 Warning Codes
Table 8-3 shows warning codes that may appear on the Universal Control Box Display.
Reoccurrence of warning codes is possible if trigger conditions are met.
Table 8-3 Warning Codes
Warning
Code
Trigger
Condition
System Response
Latch Until
Possible Cause
0001
Both Up and
Down switches
detected
simultaneously.
(Local and
Remote
switches
conflict)
Conflicting Mast
Up/Mast Down
Switch Commands
Warning
(WRN 0001):
Disable the Motor
Outputs unless the
OVERRIDE Switch
is also active.
•
One or both of
the conflicting
switch inputs
are no longer
active
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
One or both
Switch(es) are
being held on
•
One or more
Switch(es) are
damaged
•
Water ingress
may be activating
switch input(s)
•
Cable or
connection failure
0002
System voltage
has dropped
below 20 VDC
for 5
consecutive
seconds.
(Remaining
above 18 VDC)
Low Volts Warning
(WRN 0002):
Allow all mast
normal functions.
•
System
voltage
reaches 21
VDC for 5
consecutive
seconds.
- or -
•
System power
is cycled and
trigger
conditions
cleared
•
Excessive battery
drain without
sufficient charge
current/time
•
High Motor current
due to mast
resistance or large
payload
Continued