P
OSITION
I
T
PI-150
AND
PI-75
TP-5129001-J
2-7
January 2022
7. Pull the wires still in the positioner through the hole at the side egress.
Figure 2-8 Pull the Wires out the Bottom of the Positioner
8. Reconnect the quick connect between the wires from the positioner and the plug making
sure the gasket is in place.
9. Gently push the wires into the positioner and secure the gasket and removable plug in
place at the bottom of the mounting pedestal (Figure 2-9). If the gasket is not properly
installed, the positioner will leak and become damaged voiding the warranty.
Figure 2-9 Secure the Gasket and Removable Plug to the Bottom Egress