background image

 

35 

Idenfy and posion log ’G’ as shown in the picture below. 

Idenfy and posion log ’H’ as shown in the picture below. 

Idenfy and posion log ’F’ as shown in the picture below. 

Содержание BF960SL

Страница 1: ...stomer is able to fully operate the appliance and is aware of any cleaning or maintenance requirements BF960SL BALANCED FLUE ROOM SEALED GAS FIRE Model numbers F 111XX2 SLIDE for use on Natural Gas G2...

Страница 2: ...on to the appliance 14 Record data plate informa on 14 Installing the appliance into the outer box 15 Connec ng the appliance to the gas supply 15 Fi8ng the terminal 16 Connec ng the terminal guard 17...

Страница 3: ...r SAP Standard Assessment Procedure for energy ra ng of UK dwellings Ven la on No purpose made ven la on is required for this appliance This appliance must only be installed in accordance with BS5440...

Страница 4: ...inal on the same wall 1500mm N Horizontally from a terminal on the same wall 300mm In addi on the terminal should not be nearer than 300mm to an opening in the building fabric formed for the purpose o...

Страница 5: ...UT INCORRECTLY FLUE CUTTING INFORMATION IS ON PAGE 14 OF THESE INSTRUCTIONS Figure 3 shows the appliance dimensions This should be used to determine where the re will be installed into the customers p...

Страница 6: ...using a Philips headed screwdriver Using an appropriately sized Philips headed screwdriver carefully unscrew the two screws visible between the gap between the trim the side of the glass door Once th...

Страница 7: ...hand hinge Move this corner towards you so it is clear of the hinge With the door held rmly slide the glass assembly to the right and it will release from the right hand hinge Move this corner towards...

Страница 8: ...used only for transporta on purposes Once removed they can be discarded Now remove the 2 screws and two nuts which x the re into the outer box These parts will be needed to re t the appliance a er the...

Страница 9: ...ner leaf brickwork should either be steel or reinforced precast concrete The lintel should be the depth of the inner brickwork and be at least 1500mm long Mark the wall at the appropriate place checki...

Страница 10: ...e using the 8mm restrictor isola on valve supplied with the appliance If any part of the gas pipe will be situated in the cavity it MUST be sleeved in accordance with BS6891 Flexible sleeving is permi...

Страница 11: ...ox so that the front protruding lip of the outer box is ush with the exis ng plastered wall The non combus ble board which will be installed a er the box is secured should sit into this reveal If the...

Страница 12: ...be drilled to approxi mately half the brick depth then complete the hole by drilling from the outside of the building this will ensure that the entry and exit of the hole are clean Mark the xing posi...

Страница 13: ...mum open area of 100cm2 Con nue with the installa on whilst referring to the cavity wall installa on in the previous pages Again care should be taken to use a suitable non combus ble board i e Promafo...

Страница 14: ...t face of the inside wall to the outside face of the outside brickwork IMPORTANT NOTE IF THE APPLIANCE IS BEING MOUNTED WITH A SET OF SLIPS SEE PAGE 11 THEN DIMENSION A NEEDS TO BE INCREASED BY THE TH...

Страница 15: ...rrect posi on The appliance should locate on the two threaded studs at the top le and right of the outer box Take care that the appliance is fully rearward and these two studs can be seen protruding t...

Страница 16: ...ealant silicone on the rear face x it to the wall using the 4 screws and plugs provided Now t the 3 screws to secure the outer horizontal ue to the cover plate See adjacent diagram FITTING THE TERMINA...

Страница 17: ...it is recommended that the terminal guard is always Med Refer to page 4 where the diagram shows where a guard should be Med and allowable distances from the terminal This diagram shows the method of...

Страница 18: ...tate inwards and sit down on its lower edge 3 Finally t the side glass panels and side liners as shown here Slide the liner in rst and then slide the glass side panel in un l it touches the rear glass...

Страница 19: ...and eye protec on A er handling wash hands thoroughly and any other exposed parts which may have come in to contact with the material If a vacuum cleaner is used to clean the fuel bed or areas around...

Страница 20: ...n li the lever to the HIGH posi on Allow the appliance to run for a minimum period of 5 minutes Next check that the inlet pressure to the appliance is 20 mbar 1 mbar To turn o the appliance li the sli...

Страница 21: ...sumer to ensure that they are aware of trim removal and reinstalla on for baMery changes see page 20 for details of electronic igniter loca on REFIT THE TRIM AND OUTER TRIM Recheck the appliance opera...

Страница 22: ...la on to allow the odour to disperse Advise that no rubbish should be thrown onto the appliance and that the appliance should be cleaned regularly A vacuum cleaner can be used but it is important that...

Страница 23: ...able by contac ng the manufacturer directly nd details at the back of this manual Cleaning of these components should only be undertaken once the appliance is switched o and has been allowed to cool f...

Страница 24: ...ing components The following informa on details the major control components Once removed refer to the relevant sec on that follows detailing the removal of the speci c component s Turn o the gas supp...

Страница 25: ...wung outwards A er the isolator valve has been restricted remove the four screws shown in the rst diagram Pull the control module o the loca ng pin as shown in the second diagram The slide control val...

Страница 26: ...e the two 2 screws and the inlet tube nut Remove the gas tube 2 Remove the corrugated tube nut 3 Remove the pilot tube nut 4 Remove the valve locking nut and the two 2 screws 5 Remove the connector fr...

Страница 27: ...the base of the pilot 3 Remove the two 2 screws securing the pilot 4 Remove the thermocouple nut from the back of the valve Remove the two 2 screws securing the mi croswitch Remove the igniter lead fr...

Страница 28: ...ctor 1 Remove the four 4 screws to remove the log loca on pins 2 Remove the side glass and side liners out as shown below 3 Li the back glass upwards lt the lower edge outwards Remove the back glass p...

Страница 29: ...rvice of this appliance Contact details for Hearth Products Ltd can be found on the back page of these instruc ons Replacement of the Injector con nued 4 Remove six 6 screws to remove ash pan 5 Remove...

Страница 30: ...a small amount of soot has fallen from the fuel bed onto the pilot assembly causing a short circuit If this is the case ensuring the appliance is o and cold this area can be cleaned with the thin noz...

Страница 31: ...part correctly These instruc ons can also be followed to remove or reinstall the fuel bed a er cleaning This is a procedure that can be undertaken by the customer as required and the frequency will b...

Страница 32: ...N Important note the picture below shows each log and its iden fying leMer which should be used to place the logs detailed in the next few pages There are two 2 LOG B components which are iden cal Thi...

Страница 33: ...33 Iden fy and posi on log A as shown in the picture Iden fy and posi on log B as shown in the picture below Iden fy and posi on log C as shown in the picture below...

Страница 34: ...34 Iden fy and posi on log E as shown in the picture below Iden fy and posi on the other log B as shown in the picture below Iden fy and posi on log D as shown in the picture below...

Страница 35: ...35 Iden fy and posi on log G as shown in the picture below Iden fy and posi on log H as shown in the picture below Iden fy and posi on log F as shown in the picture below...

Страница 36: ...36 Iden fy and posi on log I as shown in the picture below Iden fy and posi on log K as shown in the picture below Iden fy and posi on log J as shown in the picture below...

Страница 37: ...rk around the pilot burner assembly Leave at least 5mm from any part of the pilot Refer to page 6 for details on how to secure the glass door once the logs and ceramics are in place Iden fy and posi o...

Страница 38: ...ing pressure on full rate Min 18 5 Ensure all other gas appliances are running on full rate mbar Complete relevant sec on of warranty forms complete with Gas Safe registra on details Instruct the cust...

Страница 39: ...Gas Safe Registered Installer Full details are provided in this manual Hearth Products Ltd Unit 14 Tollgate Industrial Estate Sta ord ST16 3SU Product Fiche Manufacturer Hearth Products Ltd Model No...

Страница 40: ...our policy of con nual product improvement some diagrams and small details may not be accurate however if there is any concern or ma8er of understanding that you feel needs to be clari ed please cont...

Отзывы: