The following procedures can and should
only
be performed by a
Gas Safe registered installer
.
This appliance should be serviced annually by a Gas Safe registered installer.
Removal / Replacement of Gas Carrying Components.
The removal and replacement of all the gas carrying components will require the removal of the outer trim (see
page 6) where access can then be gained to all gas carrying components. The following informaon details the
major control components. Once removed, refer to the relevant secon that follows detailing the removal of the
specific component(s).
Turn off the gas supply at the isolaon valve on the appliance. Ensure the appliance is cold.
Remove the glass door (see earlier in this manual)
and fuel effect components - put in a suitable locaon
where they cannot be damaged.
Disconnect the gas supply from the restrictor elbow.
The diagram below shows the locaon/removal of the control lever, the restrictor elbow and the electronic igniter.
SERVICE INSTRUCTIONS