Wilden A2 B Original Plastic Скачать руководство пользователя страница 21

19

WILDEN PUMP & ENGINEERING, LLC

WIL-10070-E-03

1

DIN Flange: Polypropylene = 02-5160-20-404, PVDF = 02-5160-21-404

*Refer to corresponding elastomer chart in Section 10 for correct part number.

0263 Pump Specialty Code = Solenoid-Operated, 24V DC

All boldface items are primary wear parts.

A2P ACCU-FLO™

RUBBER-FITTED

PTFE-FITTED

Item 

No.

Part Description

Qty. Per 

Pump

A2P/PKPPP/0263 

P/N

A2P/KKPPP/0263 

P/N

A2P/PKPPP/0263 

P/N

A2P/KKPPP/0263 

P/N

1

Pro-Flo

®

 Air Valve Assembly

1

01-2010-20

01-2010-20

01-2010-20

01-2010-20

2

End Cap

1

01-2332-20

01-2332-20

01-2332-20

01-2332-20

3

O-Ring, End Cap

1

01-2395-52

01-2395-52

01-2395-52

01-2395-52

4

Gasket, Air Valve

2

01-2615-52

01-2615-52

01-2615-52

01-2615-52

5

Screw, HSHC, Air Valve

4

01-6000-03

01-6000-03

01-6000-03

01-6000-03

6

Nut, Hex

4

04-6400-03

04-6400-03

04-6400-03

04-6400-03

7

Pro-Flo

®

 Solenoid Spacer

1

01-2160-20

01-2160-20

01-2160-20

01-2160-20

8

Center Section Assembly

1

02-3140-20

02-3140-20

02-3140-20

02-3140-20

9

Bushing Reducer

1

01-6950-20

01-6950-20

01-6950-20

01-6950-20

10

Pilot Sleeve Plug

1

02-2285-99

02-2285-99

02-2285-99

02-2285-99

11

Glyd™ Ring II

2

02-3210-55-225

02-3210-55-225

02-3210-55-225

02-3210-55-225

12

Retaining Ring

2

00-2650-03

00-2650-03

00-2650-03

00-2650-03

13

Muffler Plate

1

01-3181-20

01-3181-20

01-3181-20

01-3181-20

14

Gasket, Muffler Plate

1

01-3505-52

01-3505-52

01-3505-52

01-3505-52

15

Muffler

1

02-3510-99

02-3510-99

02-3510-99

02-3510-99

16

Shaft Pro-Flo

®

1

02-3810-09

02-3810-09

02-3810-09

02-3810-09

17

Disc Spring

2

02-6802-08

02-6802-08

02-6802-08

02-6802-08

18

Coil

1

00-2110-99-150

00-2110-99-150

00-2110-99-150

00-2110-99-150

19

Terminal Connector

1

00-2130-99

00-2130-99

00-2130-99

00-2130-99

20

Inner Piston

2

02-3701-01

02-3701-01

02-3751-01

02-3751-01

21

Outer Piston

2

02-4550-21-500

02-4550-21-500

02-4600-21-500

02-4600-21-500

22

Liquid Chamber

2

02-5001-20-400

02-5001-21-400

02-5001-20-400

02-5001-21-400

23

Manifold Tee Section

2

2

02-5160-20-400

02-5160-21-400

02-5160-20-400

02-5160-21-400

24

Top Retainer

2

02-5411-20-400

02-5411-21-400

02-5411-20-400

02-5411-21-400

25

Bottom Retainer

2

02-5420-20-400

02-5420-21-400

02-5420-20-400

02-5420-21-400

26

Valve Seat

4

02-1120-20-400

02-1120-21-400

02-1120-20-400

02-1120-21-400

27

Valve Seat O-Ring*

4

*

*

02-1200-60-400

02-1200-60-400

28

Top Retainer O-Ring*

2

*

*

02-1220-60

02-1220-60

29

Bottom Retainer O-Ring

2

*

*

02-1230-60

02-1230-60

30

Valve Ball*

4

*

*

02-1080-55

02-1080-55

31

Diaphragm*

2

*

*

02-1010-55

02-1010-55

32

Back-up Diaphragm

2

N/R

N/R

02-1060-51

02-1060-51

33

Tee Section O-Ring*

4

*

*

02-1300-60-400

02-1300-60-400

34

Clamp Band Assembly

2

02-7300-03-400

02-7300-03-400

02-7300-03-400

02-7300-03-400

35

Clamp Band Bolt 5⁄16”-18 x 1-3⁄4”

4

08-6050-03-500

08-6050-03-500

08-6050-03-500

08-6050-03-500

36

Clamp Band Nut 5⁄16”-18

4

08-6400-03

08-6400-03

08-6400-03

08-6400-03

37

Air Valve Bolt

4

04-6000-03

04-6000-03

04-6000-03

04-6000-03

38

Fitting, Air Inlet

2

00-2170-20

00-2170-20

00-2170-20

00-2170-20

39

Adapter Block

1

00-2155-20

00-2155-20

00-2155-20

00-2155-20

Expanded PTFE Gasket Kit (Not Shown)

1

N/R

N/R

02-9500-99

02-9500-99

Solenoid-Operated Valve Assembly  Options

 (consists of valve body, coil and connector)

Pump Models Designating Specialty Code #

Part Number

Description

151

02-2000-99-151

24V AC / 12V DC Valve Assembly

153

02-2000-99-153

24V AC / 12V DC Valve Assembly (Nema 7)

150

02-2000-99-150

24V DC Valve Assembly

154

02-2000-99-154

24V DC Valve Assembly (Nema 7)

157

02-2000-99-157

International 24V DC Valve Assembly1

155

02-2000-99-155

110V AC Valve Assembly

156

02-2000-99-156

110V AC Valve Assembly (Nema 7)

Item 1    Main Valve Body Options

Part Number

Description

02-2000-01-150

Main Valve Body

02-2000-01-154

Main Valve Body (Nema 7)

Item 2    Coil Options

Pump Models Designating Specialty Code #

Part Number

Description

150

00-2110-99-150

24V DC Coil

151

00-2110-99-151

24V AC Coil

153

00-2110-99-153

24V AC, Nema 7 Coil

154

00-2110-99-154

24V DC, Nema 7 Coil

155

00-2110-99-155

110V AC Coil

156

00-2110-99-156

110V AC Nema 7 Coil

157

00-2110-99-157

International 24V DC Coil

1

1

Meets European standards and regulations; CENELEC/PTB File #EX-91.C.2027.

Содержание A2 B Original Plastic

Страница 1: ...EOM S i m p l i f y y o u r p r o c e s s Engine e ri n g Opera ti o n Maint e n a n ce Original Series PLASTIC Pumps A2 WIL 10070 E 03 REPLACES WIL 10070 E 02...

Страница 2: ...TION 6 70 30 OPERATING CONDITION A A2T PLASTIC Rubber Fitted T Series Center Section 8 A A2T PLASTIC PTFE Fitted T Series Center Section 8 B A2P PLASTIC Rubber Fitted P Series Center Section 8 B A2P P...

Страница 3: ...ly pressure CAUTION Plastic series pumps are made of virgin plastic and are not UV stabilized Direct sunlight for prolonged periods can cause deterioration of plastics CAUTION Before any maintenance o...

Страница 4: ...l SS outer pistons DIN flange 0458 A2 Plastic Accu Flo 24V DC coil Wil Gard II 220V DIN flange 0567 Split manifold Accu Flo 24V DC coil 0570 Split manifold Accu Flo 24V AC 12V DC coil 0509 adapter blo...

Страница 5: ...let valve ball and fill the liquid chamber see shaded area FIGURE 2 When the solenoid valve is deenergized the air valve redirects pres surized air to the back side of diaphragm B The pressurized air...

Страница 6: ...F H G J H J M K L R N P B C D E F G M 25 mm 1 ANSI DIN FLANGE LIQUID INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE FLANGE 150 pound class DIMENSIONS ITEM METRIC mm STANDARD inch A 297 11 7 B 74 2 9 C...

Страница 7: ...INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE 25 mm 1 ANSI DIN FLANGE LIQUID INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE DIMENSIONS ITEM METRIC mm STANDARD inch A 297 11 7 B 74 2 9 C 147 5 8 D 307...

Страница 8: ...pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve Nm3 h LPM Height 335 mm 13 2 Width 297 mm 11 7 Depth 239 mm 9 4 Est Ship Weight Polyp...

Страница 9: ...umps should be specified so that daily operation parameters will fall in the center of the pump performance curve Nm3 h LPM SECTION 5D PERFORMANCE CURVES A2P PLASTIC PTFE FITTED Height 356 mm 14 0 Wid...

Страница 10: ...odified under static air and fluid pressure condition This curve can be applied to different pressure conditions to estimate the change in flow due to stroke rate 0 7ATER ISCHARGE LOW 2ATE These curve...

Страница 11: ...rge enough to supply the volume of air necessary to achieve the desired pumping rate Consult manual for perfor mance information The use of an air filter before the pump will ensure that the majority...

Страница 12: ...essure viscosity and abrasiveness of process fluid all effect the parts life of a Wilden pump Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime Pers...

Страница 13: ...ck for sticking ball check valves If the material being pumped is not compatible with the pump elastomers swelling may occur Replace ball check valves and o ring with the proper elastomers 5 Check to...

Страница 14: ...comes in both PVDF and polypropylene The single piece center section consisting of center block and air chambers is molded of polypropylene All o rings used in the pump are of a special material and s...

Страница 15: ...p bands that secure the liquid cham bers to the center section Step 9 Figure 9 Rotate the clamp bands so that they can be removed Step 4 Figure 4 Remove the top liquid retainer to expose the valve bal...

Страница 16: ...mbly from center section assembly Step 13 Figure 13 To remove the remaining diaphragm assembly from the shaft secure shaft with soft jaws a vise fitted with plywood or other suitable material to ensur...

Страница 17: ...ean the inside of the center section shaft bushing to ensure no damage is done to new seals Stainless bolts should be lubed to reduce the possibility of seizing during tightening Be sure to tighten ou...

Страница 18: ...16 WILDEN PUMP ENGINEERING LLC WIL 10070 E 03 Adapter Block Version SECTION 9A EXPLODED VIEW PARTS LISTING A2T PLASTIC ACCU FLO PTFE Assembly...

Страница 19: ...hragm 2 N R N R 02 1060 51 02 1060 51 27 Tee Section O Ring 4 02 1300 60 400 02 1300 60 400 28 Clamp Band Assembly 2 02 7300 03 400 02 7300 03 400 02 7300 03 400 02 7300 03 400 29 Clamp Band Bolt 5 16...

Страница 20: ...18 WILDEN PUMP ENGINEERING LLC WIL 10070 E 03 SECTION 9B EXPLODED VIEW PARTS LISTING A2P PLASTIC ACCU FLO Standard Assembly Adapter Block Version PTFE Assembly...

Страница 21: ...2 5160 21 400 02 5160 20 400 02 5160 21 400 24 Top Retainer 2 02 5411 20 400 02 5411 21 400 02 5411 20 400 02 5411 21 400 25 Bottom Retainer 2 02 5420 20 400 02 5420 21 400 02 5420 20 400 02 5420 21 4...

Страница 22: ...1010 56 02 1080 56 N A N A N A N A Wil Flex Orange 02 1010 58 02 1080 58 02 1200 58 400 02 1300 58 400 02 1220 58 02 1230 58 Neoprene Backup Black 02 1060 511 N A N A N A N A N A 1 Saniflex back up di...

Страница 23: ...omes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...

Отзывы: